CD4042AD3

Microcircuits, Electronic

MICROCIRCUIT,DIGITAL

CD4042AD3

5962-01-015-0281

5962 - Microcircuits, Electronic

Intersil Corporation

MICROCIRCUIT,DIGITAL

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • End Item Identification

    calibration standards equipment; an/bqh-5 sonar data collecting set; spruance class dd (963); mobile subscriber equipment (mse); deep submergence systems programs (dssp); switchboard, telephone, automatic (sb-3614(v)/tt); ticonderoga class cg (47); blue

  • Criticality Code Justification

    feat

  • Body Width

    0.240 inches minimum and 0.260 inches maximum

  • Special Features

    weapon system essential

  • Features Provided

    dynamic and programmable and low power and w/buffered output and complementary outputs and w/strobe and w/enable and hermetically sealed and positive outputs and monolithic and negative edge triggered

  • Input Circuit Pattern

    6 input

  • Test Data Document

    96906-mil-std-883 standard (includes industry or association standards, individual manufactureer standards, etc.).

  • Output Logic Form

    complementary-metal oxide-semiconductor logic

  • Terminal Type And Quantity

    16 printed circuit

  • Storage Temp Range

    -65.0/+150.0 deg celsius

  • Design Function And Quantity

    4 latch, d, clocked

  • Body Length

    0.745 inches minimum and 0.785 inches maximum

  • Terminal Surface Treatment

    solder

  • Inclosure Material

    ceramic and glass

  • Case Outline Source And Designator

    -0-001-ae joint electron device engineering council

  • Inclosure Configuration

    dual-in-line

  • Voltage Rating And Type Per Characteristic

    -0.5 volts minimum power source and 15.5 volts maximum power source

  • Maximum Power Dissipation Rating

    200.0 milliwatts

  • Body Height

    0.055 inches minimum and 0.140 inches maximum

  • Time Rating Per Chacteristic

    300.00 nanoseconds maximum propagation delay time, low to high level output and 300.00 nanoseconds maximum propagation delay time, high to low level output

  • Operating Temp Range

    -55.0/+125.0 deg celsius

  • ~1

    ridge class lcc-19; tarawa class lha

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...