CD4042AE

Microcircuits, Electronic

MICROCIRCUIT,DIGITAL

CD4042AE

5962-01-015-0281

5962 - Microcircuits, Electronic

Intersil Corporation

MICROCIRCUIT,DIGITAL

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • End Item Identification

    calibration standards equipment; an/bqh-5 sonar data collecting set; spruance class dd (963); mobile subscriber equipment (mse); deep submergence systems programs (dssp); switchboard, telephone, automatic (sb-3614(v)/tt); ticonderoga class cg (47); blue

  • Criticality Code Justification

    feat

  • Body Width

    0.240 inches minimum and 0.260 inches maximum

  • Special Features

    weapon system essential

  • Features Provided

    dynamic and programmable and low power and w/buffered output and complementary outputs and w/strobe and w/enable and hermetically sealed and positive outputs and monolithic and negative edge triggered

  • Input Circuit Pattern

    6 input

  • Test Data Document

    96906-mil-std-883 standard (includes industry or association standards, individual manufactureer standards, etc.).

  • Output Logic Form

    complementary-metal oxide-semiconductor logic

  • Terminal Type And Quantity

    16 printed circuit

  • Storage Temp Range

    -65.0/+150.0 deg celsius

  • Design Function And Quantity

    4 latch, d, clocked

  • Body Length

    0.745 inches minimum and 0.785 inches maximum

  • Terminal Surface Treatment

    solder

  • Inclosure Material

    ceramic and glass

  • Case Outline Source And Designator

    -0-001-ae joint electron device engineering council

  • Inclosure Configuration

    dual-in-line

  • Voltage Rating And Type Per Characteristic

    -0.5 volts minimum power source and 15.5 volts maximum power source

  • Maximum Power Dissipation Rating

    200.0 milliwatts

  • Body Height

    0.055 inches minimum and 0.140 inches maximum

  • Time Rating Per Chacteristic

    300.00 nanoseconds maximum propagation delay time, low to high level output and 300.00 nanoseconds maximum propagation delay time, high to low level output

  • Operating Temp Range

    -55.0/+125.0 deg celsius

  • ~1

    ridge class lcc-19; tarawa class lha

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.