6AG12P
Relays and Solenoids
RELAY,ELECTROMAGNETIC
6AG12P
RELAY,ELECTROMAGNETIC
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Mounting Facility Type And Quantity
1 plug-in terminal single mounting facility
-
Duty Type
continuous
-
Winding Dc Resistance Rating
675.0 ohms nominal single winding
-
Overall Height
0.653 inches maximum
-
Coil Quantity
1
-
Main Contact Load Current Rating At Maximum Rated Voltage
2.0 amperes ac resistive load and 2.0 amperes dc resistive load
-
Overall Length
1.266 inches maximum
-
Terminal Type And Quantity
8 pin all functions
-
Specification/Standard Data
81349-mil-r-5757/10 government specification
-
Main Contact Maximum Voltage Rating In Volts
115.0 ac and 28.0 dc
-
Operating Voltage Rating And Type At Specified Temp
26.5 volts teardrop, two holes type 4f single winding
-
Winding Quantity
1
-
Environmental Protection
hermetic
-
Time Delay
0.006 seconds maximum fixed operate and release time
-
Nonpile-Up Main Contact Arrangement
2 pole, double throw, one position momentary
-
Overall Width
0.800 inches maximum
-
~1
data on certain environmental and performance
-
Test Data Document
81349-mil-r-5757 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type