SM-A-742459-2

Filters and Networks

FILTER,BAND PASS

SM-A-742459-2

5915-01-015-8307

5915 - Filters and Networks

Us Army Communications &

FILTER,BAND PASS

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Overall Height

    0.700 inches maximum

  • Body Length

    4.030 inches maximum

  • Body Height

    0.510 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    3.500 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.750 inches nominal

  • Operating Temp Range

    m18.0/p75.0 deg celsius

  • Average Life Rating In Hours

    26280.0

  • Reference Frequency Per Function

    1.209 kilohertz 1st band pass

  • Reference Frequency Per Function

    1.336 kilohertz 2nd band pass

  • Reference Frequency Per Function

    1.477 kilohertz 3rd band pass

  • Source Impedance Rating Per Function

    1.0 kilohms 1st band pass

  • Source Impedance Rating Per Function

    1.0 kilohms 2nd band pass

  • Source Impedance Rating Per Function

    1.0 kilohms 4th band pass

  • Source Impedance Rating Per Function

    1.0 kilohms 5th band pass

  • Load Impedance Per Function

    1.0 kilohms 1st band pass

  • Load Impedance Per Function

    1.0 kilohms 3rd band pass

  • Load Impedance Per Function

    1.0 kilohms 4th band pass

  • Principal Circuitry Type Per Function

    inductance-capacitance 1st band pass

  • Principal Circuitry Type Per Function

    inductance-capacitance 2nd band pass

  • Principal Circuitry Type Per Function

    inductance-capacitance 4th band pass

  • Inclosure Type

    hermetically sealed

  • Mounting Facility Type And Quantity

    14 pin

  • Insertion Loss At Reference Frequency Per Function In Decibels

    3.0 4th band pass

  • Functional Terminal Type And Quantity

    1 pin input

  • Specified Frequencies Of Discrimination Per Function

    1.296 kilohertz 2nd band pass and 1.309 kilohertz 2nd band pass and 1.362 kilohertz 2nd band pass and 1.377 kilohertz 2nd band pass

  • Specified Frequencies Of Discrimination Per Function

    1.433 kilohertz 3rd band pass and 1.448 kilohertz 3rd band pass and 1.506 kilohertz 3rd band pass and 1.522 kilohertz 3rd band pass

  • Specified Frequencies Of Discrimination Per Function

    1.584 kilohertz 4th band pass and 1.600 kilohertz 4th band pass and 1.665 kilohertz 4th band pass and 1.682 kilohertz 4th band pass

  • Frequency Band Width Per Function

    1.185 kilohertz 1st band pass and 1.233 kilohertz 1st band pass

  • Frequency Band Width Per Function

    1.309 kilohertz 2nd band pass and 1.362 kilohertz 2nd band pass

  • Frequency Band Width Per Function

    1.448 kilohertz 3rd band pass and 1.506 kilohertz 3rd band pass

  • Frequency Band Width Per Function

    2.549 kilohertz 5th band pass and 2.651 kilohertz 5th band pass

  • Discrimination At Specified Frequencies Per Function In Decibels

    3.0 minimum 1st band pass and 30.0 maximum 1st band pass

  • Discrimination At Specified Frequencies Per Function In Decibels

    3.0 minimum 2nd band pass and 30.0 maximum 2nd band pass

  • Discrimination At Specified Frequencies Per Function In Decibels

    3.0 minimum 3rd band pass and 30.0 maximum 3rd band pass

  • Discrimination At Specified Frequencies Per Function In Decibels

    3.0 minimum 5th band pass and 30.0 maximum 5th band pass

  • Unpackaged Unit Weight

    8.000 ounces

  • Body Width

    2.280 inches maximum

  • Reference Frequency Per Function

    1.633 kilohertz 4th band pass

  • Reference Frequency Per Function

    2.6 kilohertz 5th band pass

  • Source Impedance Rating Per Function

    1.0 kilohms 3rd band pass

  • Load Impedance Per Function

    1.0 kilohms 2nd band pass

  • Load Impedance Per Function

    1.0 kilohms 5th band pass

  • Principal Circuitry Type Per Function

    inductance-capacitance 3rd band pass

  • Principal Circuitry Type Per Function

    inductance-capacitance 5th band pass

  • Insertion Loss At Reference Frequency Per Function In Decibels

    3.0 1st band pass

  • Insertion Loss At Reference Frequency Per Function In Decibels

    3.0 2nd band pass

  • Insertion Loss At Reference Frequency Per Function In Decibels

    3.0 3rd band pass

  • Insertion Loss At Reference Frequency Per Function In Decibels

    3.0 5th band pass

  • Functional Terminal Type And Quantity

    1 pin ground

  • Functional Terminal Type And Quantity

    5 pin output

  • Specified Frequencies Of Discrimination Per Function

    1.173 kilohertz 1st band pass and 1.185 kilohertz 1st band pass and 1.233 kilohertz 1st band pass and 1.246 kilohertz 1st band pass

  • Specified Frequencies Of Discrimination Per Function

    2.522 kilohertz 5th band pass and 2.549 kilohertz 5th band pass and 2.651 kilohertz 5th band pass and 2.678 kilohertz 5th band pass

  • Body Material

    metal

  • Frequency Band Width Per Function

    1.600 kilohertz 4th band pass and 1.665 kilohertz 4th band pass

  • Discrimination At Specified Frequencies Per Function In Decibels

    3.0 minimum 4th band pass and 30.0 maximum 4th band pass

  • Body Surface Treatment

    tin

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...