TTM-6150-1
Coils and Transformers
TRANSFORMER,POWER
TTM-6150-1
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Center To Center Distance Between Mounting Facilities Parallel To Length
5.562 inches nominal
-
Mounting Slot Width
0.203 inches nominal
-
Input-Output Phase Relationship
single phase to single phase
-
Winding Shielding Method
internal shield grounded to inclosure
-
Body Length
6.000 inches nominal
-
Body Width
2.812 inches maximum
-
Inclosure Type
fully inclosed
-
Mounting Facility Quantity
4
-
Mounting Method
flange and slot
-
Winding Function And Quantity
2 primary and 4 secondary
-
Winding Operating Current
5.0 amperes dc maximum
-
Winding Operating Voltage
20.50 ac volts nominal
-
Winding Operating Voltage
47.00 ac volts nominal
-
Winding Operating Voltage
66.00 ac volts nominal
-
Terminal Type And Quantity
14 tab,solder lug
-
Reliability Indicator
not established
-
Center To Center Distance Between Mounting Facilities Parallel To Width
2.250 inches nominal
-
Frequency Rating
55.0 hertz minimum and 440.0 hertz maximum
-
Body Height
3.375 inches nominal
-
Winding Tap Location
center tap
-
Winding Operating Current
10.0 milliamperes dc maximum
-
Winding Operating Current
100.0 milliamperes dc maximum
-
Winding Operating Current
15.0 amperes dc maximum
-
Winding Operating Voltage
100.00 ac volts nominal
-
Winding Operating Voltage
115.00 ac volts nominal