MIL-PRF-39016/12
Relays and Solenoids
RELAY,ELECTROMAGNETIC
MIL-PRF-39016/12
RELAY,ELECTROMAGNETIC
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Test Data Document
81349-mil-r-39016 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type
-
~1
data on certain environmental and performanc
-
Fragility Factor
moderately rugged
-
Specification/Standard Data
81349-mil-r-39016/12 government specification
-
Storage Type
general purpose warehouse
-
Criticality Code Justification
feat
-
Nonpile-Up Main Contact Arrangement
2 pole, double throw, one position momentary
-
Special Features
failure rate level of 3.000 percent per 10000 cycles
-
Winding Dc Resistance Rating
61.0 ohms nominal all windings
-
Environmental Protection
hermetic
-
Overall Diameter
0.370 inches maximum
-
Main Contact Load Current Rating At Maximum Rated Voltage
500.0 milliamperes ac resistive load and 1.0 amperes dc resistive load
-
Main Contact Load Current Rating At Maximum Rated Voltage
100.0 milliamperes dc lamp load
-
Mounting Facility Type And Quantity
1 terminal single mounting facility
-
Winding Quantity
2
-
Main Contact Maximum Voltage Rating In Volts
115.0 ac and 28.0 dc
-
Coil Quantity
2
-
Operating Voltage Rating And Type At Specified Temp
5.0 volts teardrop, two holes type 4f all windings
-
Purpose For Which Designed
general
-
Main Contact Load Current Rating At Maximum Rated Voltage
200.0 milliamperes dc inductive load
-
Overall Length
0.280 inches maximum
-
Terminal Type And Quantity
10 wire lead all functions
-
Duty Type
continuous
-
Time Delay
0.002 seconds maximum fixed operate time
-
Features Provided
polarized and latching contacts