SM3HK5-50VDC2
Circuit Breakers
CIRCUIT BREAKER
SM3HK5-50VDC2
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Trip Delay Time In Seconds Per Rated Continuous Current
1.200 nominal at 150 pct single location and 0.100 nominal at 200 pct single location and 0.030 nominal at 300 pct single location and 0.500 nominal at 125 pct single location and 0.007 nominal at 500 pct single location and 0.005 nominal at 1000 pct
-
Fragility Factor
moderately rugged
-
Terminal Type And Quantity
2 wire hook
-
Special Handling Feature
magnetic
-
Reset Method
manual
-
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
-
Actuator Position Designation
at pole one
-
Storage Type
general purpose warehouse
-
Inclosure Protection Type For Which Designed
explosion resistant and fungus resistant and shockproof and dustproof and vibrationproof
-
Actuator Function
trip-reset
-
Switch Voltage Rating And Type In Volts
125.0 ac and 50.0 dc
-
Nominal Thread Size
0.375 inches
-
Thread Quantity Per Inch
32
-
Circuit Protection Type
overcurrent single location
-
Switch Contact Arrangement
single pole, double throw
-
Center To Center Distance Between Terminals Parallel To Length
0.875 inches nominal
-
Bushing Length
0.375 inches maximum
-
Pole Quantity
1
-
Case Material
metal
-
Manual Actuator Type And Quantity
1 toggle
-
Internal Trip Release Configuration
series trip single location
-
Body Length
1.500 inches maximum
-
Trip Release Characteristic
time delay single location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
500.0 dc single location
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
-
Main Contact Tripping Mechanism Type
trip free
-
Arc Quenching Method
magnetic blowout
-
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc single location
-
Body Style
single pole type
-
Body Width
0.625 inches maximum
-
Trip Release Method
magnetic-hydraulic single location
-
Mounting Surface To Terminal End Distance
1.605 inches maximum
-
Switch Terminal Type
pin
-
Thread Series Designator
unef
-
Auxiliary Switch Function And Quantity
1 alarm
-
Maximum Continuous Load Current Rating Per Pole
5.0 amperes dc single location
-
Switch Current Rating And Type In Amps
1.0 ac and 0.5 dc
-
~1
single location
-
Switch Location And Position Designation
internal at pole one