0111-32VDC8 1-2AMPCURVE2

Circuit Breakers

CIRCUIT BREAKER

0111-32VDC8 1-2AMPCURVE2

5925-01-016-7039

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Style

    13a single pole type

  • Body Length

    3.209 inches minimum and 3.229 inches maximum

  • Body Width

    1.459 inches minimum and 1.479 inches maximum

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    2.490 inches minimum and 2.510 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.302 inches minimum and 1.320 inches maximum

  • Iii Fragility Factor

    moderately rugged

  • Iii End Item Identification

    general application electronics (gen-ap-e)

  • Iii Arc Quenching Method

    magnetic blowout

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Iii Storage Type

    general purpose warehouse

  • Maximum Continuous Load Current Rating Per Pole

    8.5 amperes dc single location

  • Operating Voltage Type And Rating Per Pole In Volts

    32.0 dc single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 dc single location

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Characteristic

    time delay single location

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Actuator Position Designation

    at pole one

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.200 minimum at 200 pct and 7.500 maximum at 200 pct single location

  • Manufacturers Code

    08125

  • Body Height

    2.630 inches minimum and 2.650 inches maximum

  • Boss Height

    0.115 inches minimum and 0.135 inches maximum

  • Pole Quantity

    1

  • Thread Quantity Per Inch

    32

  • Trip Release Method

    magnetic-hydraulic single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.138 inches

  • Inclosure Protection Type For Which Designed

    dustproof

  • Design Control Reference

    0111-81/2amp32vdc curve2

  • Thread Series Designator

    unc

  • Terminal Type And Quantity

    2 screw

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...