UPG-66-3-6-2-303

Circuit Breakers

CIRCUIT BREAKER

UPG-66-3-6-2-303

5925-01-018-4545

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Length

    2.000 inches nominal

  • Body Width

    1.500 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.660 inches nominal

  • Arc Quenching Method

    magnetic blowout

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac

  • Trip Release Method

    magnetic-hydraulic

  • Trip Release Characteristic

    time delay

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole one

  • Internal Trip Release Configuration

    shunt trip

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.200 minimum at 200 pct and 20.000 maximum at 200 pct

  • Inclosure Protection Type For Which Designed

    moisture resistant

  • Thread Series Designator

    unc

  • Terminal Type And Quantity

    5 screw

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    1.530 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.750 inches nominal

  • Fragility Factor

    moderately rugged

  • Boss Height

    0.130 inches nominal

  • Mounting Surface To Terminal End Distance

    2.032 inches maximum

  • Pole Quantity

    2

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Maximum Continuous Load Current Rating Per Pole

    30.0 amperes ac

  • Circuit Protection Type

    overcurrent

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Nominal Thread Size

    0.138 inches

  • Frequency In Hertz

    60.0

  • Unpackaged Unit Weight

    8.500 ounces

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...