2291620-7

Circuit Breakers

CIRCUIT BREAKER

2291620-7

5925-01-018-6843

5925 - Circuit Breakers

Navair And Navsea Managed

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations and 50.0 dc all locations

  • Nominal Thread Size

    0.375 inches

  • Thread Quantity Per Inch

    32

  • Trip Release Method

    magnetic all locations

  • Terminal Type And Quantity

    4 wire hook

  • Body Style

    multipole-single actuator type

  • Case Material

    metal

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Position Designation

    between pole one and two

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 all locations

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes ac all locations and 10.0 amperes dc all locations

  • Arc Quenching Method

    magnetic blowout

  • Specification/Standard Data

    81349-mil-prf-39019/3 government specification

  • Body Length

    1.562 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    0.906 inches maximum

  • Frequency In Hertz

    400.0 all locations

  • Thread Series Designator

    unef

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.550 minimum at 200 pct all locations and 1.000 maximum at 200 pct all locations

  • Body Width

    1.281 inches maximum

  • ~1

    type data on certain environmental and performa

  • Test Data Document

    81349-mil-prf-39019 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general

  • Fragility Factor

    moderately rugged

  • Special Handling Feature

    magnetic

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    2

  • Bushing Length

    0.332 inches minimum and 0.380 inches maximum

  • Reset Method

    manual

  • Center To Center Distance Between Terminals Parallel To Width

    0.594 inches minimum and 0.656 inches maximum

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Mounting Surface To Terminal End Distance

    1.828 inches maximum

  • Internal Trip Release Configuration

    series trip all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    300.0 ac all locations and 500.0 dc all locations

  • Thread Pitch Diameters

    +0.3503/+0.3537 inches

  • Inclosure Protection Type For Which Designed

    fungus resistant and hermetically sealed

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...