G88120
Coils and Transformers
TRANSFORMER,POWER
G88120
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Terminal Type And Quantity
7 tab, solder lug
-
Overall Width
3.250 inches maximum
-
Body Length
4.500 inches maximum
-
Mounting Hole Diameter
0.218 inches minimum single group and 0.224 inches maximum single group
-
Reliability Indicator
not established
-
Input-Output Phase Relationship
single phase to single phase single component
-
Winding Operating Voltage
40.00 ac volts nominal single component 2nd secondary
-
Frequency Rating
60.0 hertz nominal single component
-
Body Width
3.250 inches maximum
-
Winding Operating Voltage
440.00 ac volts nominal single component single primary
-
Body Height
7.000 inches maximum
-
Winding Operating Current
2.5 amperes ac maximum single component 2nd secondary
-
Winding Operating Current
3.0 amperes ac maximum single component 1st secondary
-
Center To Center Distance Between Mounting Facilities Parallel To Width
2.500 inches nominal single mounting facility single center group
-
Overall Length
4.500 inches maximum
-
Mounting Facility Quantity
4 single group
-
Winding Shielding Method
internal shield grounded to inclosure and core and brought out to terminal single component
-
Center To Center Distance Between Mounting Facilities Parallel To Length
3.750 inches nominal single mounting facility single center group
-
Mounting Method
flange single group and unthreaded hole single group
-
Overall Height
7.000 inches maximum
-
Winding Function And Quantity
1 primary single component and 2 secondary single component
-
Inclosure Type
fully inclosed
-
Winding Operating Voltage
115.00 ac volts nominal single component 1st secondary