40-153-1

Circuit Breakers

CIRCUIT BREAKER

40-153-1

5925-01-019-0326

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Thread Series Designator

    unc

  • Inclosure Protection Type For Which Designed

    dustproof and fungus proof

  • Actuator Position Designation

    at pole one

  • Manual Actuator Type And Quantity

    1 toggle

  • Main Contact Tripping Mechanism Type

    trip free

  • Reset Method

    manual

  • Trip Release Characteristic

    instantaneous single location

  • Circuit Protection Type

    overcurrent single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1500.0 dc single location

  • Maximum Continuous Load Current Rating Per Pole

    12.0 amperes dc single location

  • Terminal Type And Quantity

    2 screw

  • Nominal Thread Size

    0.138 inches

  • Internal Trip Release Configuration

    series trip single location

  • Actuator Function

    trip-reset

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Trip Release Method

    magnetic-hydraulic single location

  • Operating Voltage Type And Rating Per Pole In Volts

    32.0 dc single location

  • Thread Quantity Per Inch

    32

  • Special Handling Feature

    magnetic

  • Storage Type

    general purpose warehouse

  • Mounting Facility Type And Quantity

    2 threaded hole and 2 slot

  • Pole Quantity

    1

  • Case Material

    plastic

  • Body Height

    2.646 inches minimum and 2.666 inches maximum

  • Body Width

    1.458 inches minimum and 1.478 inches maximum

  • Mounting Slot Width

    0.164 inches nominal

  • Arc Quenching Method

    magnetic blowout

  • Boss Height

    0.115 inches minimum and 0.135 inches maximum

  • Fragility Factor

    moderately rugged

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.302 inches minimum and 1.322 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    2.740 inches minimum and 2.760 inches maximum

  • Body Length

    3.208 inches minimum and 3.228 inches maximum

  • Body Style

    13a single pole type

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...