204-15847-101

Circuit Breakers

CIRCUIT BREAKER

204-15847-101

5925-01-019-1250

5925 - Circuit Breakers

The Boeing Company

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    140.0 all locations

  • Terminal Type And Quantity

    6 tab w/screw

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    6000.0 ac all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    11.000 minimum at 200 pct all locations and 65.000 maximum at 200 pct all locations

  • Case Material

    plastic

  • Unpackaged Unit Weight

    0.650 pounds

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    6000.0 ac single location

  • Body Width

    2.189 inches nominal

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Body Style

    multipole-multiple actuator type

  • Trip Release Method

    thermal-magnetic all locations

  • Manual Actuator Type And Quantity

    1 push-pull

  • Actuator Position Designation

    at pole two

  • Center To Center Distance Between Terminals Parallel To Length

    1.160 inches minimum and 1.220 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.800 inches minimum and 1.820 inches maximum

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal all locations

  • Inclosure Protection Type For Which Designed

    shock resistant and vibration resistant and fungus resistant and corrosion resistant

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes ac all locations

  • Nominal Thread Size

    0.138 inches

  • Center To Center Distance Between Terminals Parallel To Width

    0.740 inches minimum and 0.760 inches maximum

  • Main Contact Tripping Mechanism Type

    trip free

  • Body Length

    2.560 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.740 inches minimum and 0.760 inches maximum

  • Operating Voltage Type And Rating Per Pole In Volts

    115.0 ac all locations

  • Frequency In Hertz

    400.0 all locations

  • Fragility Factor

    moderately rugged

  • Special Handling Feature

    magnetic

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Mounting Surface To Terminal End Distance

    2.900 inches maximum

  • Thread Series Designator

    unc

  • Reset Method

    manual

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...