0N014928
Coils and Transformers
TRANSFORMER,POWER
0N014928
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Terminal Type And Quantity
9 tab, solder lug
-
Winding Operating Voltage
115.00 ac volts nominal single component single primary
-
Cubic Measure
46.8 cubic inches
-
Mounting Method
flange and slot single group
-
Mounting Facility Quantity
4 single group
-
Maximum Operating Temp
65.0 deg celsius
-
Body Height
3.140 inches nominal
-
Body Width
4.025 inches nominal
-
Winding Shielding Method
internal shield grounded to inclosure single component
-
Input-Output Phase Relationship
single phase to single phase single component
-
Center To Center Distance Between Mounting Facilities Parallel To Width
2.500 inches nominal single mounting facility single center group
-
Reliability Indicator
not established
-
Winding Operating Current
2.5 amperes ac maximum single component 3rd secondary
-
Winding Operating Current
1.8 amperes ac maximum single component 1st secondary
-
Winding Operating Current
1.5 amperes ac maximum single component 2nd secondary
-
Winding Tap Location
center tap single component 2nd secondary
-
Winding Function And Quantity
1 primary and 3 secondary single component
-
Inclosure Type
fully inclosed
-
Body Length
3.700 inches nominal
-
Frequency Rating
50.0 hertz minimum and 60.0 hertz maximum single component
-
Mounting Slot Width
0.203 inches nominal single group
-
Center To Center Distance Between Mounting Facilities Parallel To Length
3.315 inches nominal single mounting facility single center group