ST28248
Coils and Transformers
TRANSFORMER,POWER
ST28248
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Center To Center Distance Between Mounting Facilities Parallel To Length
2.750 inches nominal single mounting facility single center group
-
Unpackaged Unit Weight (Non-Core)
1.800 pounds
-
Winding Operating Voltage
187.00 ac volts minimum single component single primary and 204.00 ac volts maximum single component single primary
-
Body Height
2.090 inches nominal
-
Input-Output Phase Relationship
three phase to three phase single component and three phase to six phase single component
-
Body Width
2.560 inches nominal
-
Winding Tap Location (Non-Core)
err-070
-
Mounting Method
threaded hole single group
-
Inclosure Type
fully inclosed
-
Winding Function And Quantity
1 primary single component and 4 secondary single component
-
Winding Operating Current
300.0 milliamperes dc minimum single component 3rd secondary and 1.25 amperes ac maximum single component 3rd secondary
-
Maximum Operating Temp
125.0 deg celsius
-
Terminal Type And Quantity
35 wire lead
-
Reliability Indicator
not established
-
Center To Center Distance Between Mounting Facilities Parallel To Width
2.062 inches nominal single mounting facility single center group
-
Frequency Rating
400.0 hertz nominal single component
-
Thread Class (Non-Core)
err-070
-
Thread Series Designator
unc single group
-
Winding Operating Voltage
14.80 ac volts nominal single component 1st secondary
-
Mounting Facility Quantity
4 single group
-
Body Length
3.250 inches nominal
-
Special Features
output currents shown as rectified
-
Winding Operating Current
170.0 milliamperes dc minimum single component 4th secondary and 2.4 amperes ac maximum single component 4th secondary
-
Nominal Thread Size
0.138 inches single group
-
Winding Operating Current
30.0 milliamperes dc maximum single component 2nd secondary
-
Winding Operating Voltage
14.80 ac volts nominal single component 2nd secondary
-
Winding Operating Voltage
15.20 ac volts nominal single component 4th secondary
-
Thread Direction (Non-Core)
err-070
-
Transformer Winding Connection Type
delta-wye
-
Winding Operating Voltage
34.10 ac volts nominal single component 3rd secondary
-
Winding Operating Current
30.0 milliamperes dc maximum single component 1st secondary