402400
Switches
SWITCH,ROTARY
402400
SWITCH,ROTARY
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Style Designator
circular wafer, bushing mount
-
First Flat Length
0.365 inches minimum single actuator and 0.385 inches maximum single actuator
-
Contact Switching Action
breaks before makes each section rear
-
Err Default
err default and err default
-
Switch Actuator Positioning Increment
60.0 degrees single actuator
-
Overall Width
1.296 inches minimum and 1.328 inches maximum
-
Test Data Document
81349-mil-s-3786 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type
-
Nominal Thread Size
0.375 inches single mounting facility
-
Contact Load Current Rating
1.0 amperes resistive load ac at sea level
-
Individual Section Quantity
5
-
Flat Height
0.214 inches minimum single actuator and 0.218 inches maximum single actuator
-
Shaft Diameter
0.247 inches minimum single actuator and 0.250 inches maximum single actuator
-
Switch Actuator Stop Device Type
fixed stop single actuator
-
Shaft Length
0.828 inches minimum single actuator and 0.858 inches maximum single actuator
-
Throw Quantity
2 each section rear
-
Contact Load Current Rating
2.0 amperes resistive load dc at sea level
-
Overall Length
3.908 inches maximum
-
Pole Quantity
3 each section rear
-
Contact Voltage Rating In Volts
28.0 dc at sea level
-
Switch Actuator Indexing Position Quantity
2 single actuator
-
Thread Series Designator
unef single mounting facility
-
Switch Contact Basic Design
nonpile-up symmetrical
-
Contact Voltage Rating In Volts
110.0 ac at sea level
-
Nonturn Device Radius
0.531 inches nominal at 4:30 o'clock
-
Terminal Type
tab, solder lug
-
Operating Temp Range
-65.0/+85.0 deg celsius
-
Nonturn Device Type
tab at 4:30 o'clock
-
Overall Height
1.516 inches minimum and 1.546 inches maximum
-
Shaft Flat/Slot Angular Location
120.0 degrees from nonturn device single actuator
-
Mounting Method
threaded bushing w/panel seal single mounting facility
-
Shaft Type
round, flatted single actuator
-
~1
data on certain environmental and performance