3020518-009

Circuit Breakers

CIRCUIT BREAKER

3020518-009

5925-01-022-4323

5925 - Circuit Breakers

Navair And Navsea Managed

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Position Designation

    at pole two

  • Nominal Thread Size

    0.375 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    3600.000 nominal at 100 pct and 3.000 minimum at 125 pct and 60.000 maximum at 125 pct and 0.500 minimum at 200 pct and 9.000 maximum at 200 pct and 0.000 minimum at 400 pct and 1.750 maximum at 400 pct all locations

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Manufacturers Code

    10001

  • Thread Series Designator

    unef

  • Terminal Type And Quantity

    6 wire hook

  • Internal Trip Release Configuration

    series trip all locations

  • Frequency In Hertz

    400.0 all locations

  • Design Control Reference

    3020518-009

  • Body Length

    1.562 inches maximum

  • Body Width

    1.937 inches maximum

  • Case Material

    metal

  • Center To Center Distance Between Terminals Parallel To Length

    0.906 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    0.625 inches nominal

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    2.0 amperes ac all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    300.0 ac all locations

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Characteristic

    time delay all locations

  • Body Style

    1b multipole-single actuator type

  • Bushing Length

    0.280 inches minimum and 0.380 inches maximum

  • Mounting Surface To Terminal End Distance

    1.828 inches maximum

  • Pole Quantity

    3

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • Trip Release Method

    magnetic all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Ultimate Trip Time Per Pole In Seconds

    0.100 nominal all locations

  • Actuator Function

    trip-reset

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...