267-0243-300

Switches

SWITCH,THERMOSTATIC

267-0243-300

5930-01-023-6938

5930 - Switches

Honeywell International Inc.

SWITCH,THERMOSTATIC

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • ~1

    degrees fahrenheit

  • Mounting Method

    threaded stud

  • Contact Voltage Rating In Volts

    30.0 dc at sea level fourth voltage

  • Err Default

    err default and err default

  • Overall Height

    0.865 inches minimum and 0.924 inches maximum

  • Thread Quantity Per Inch

    32 all threaded stud

  • Thread Class

    2a all threaded stud

  • Contact Voltage Rating In Volts

    250.0 ac at sea level first voltage

  • Style Designator

    disc

  • Frequency In Hertz

    60.0 single voltage

  • Features Provided

    hermetically sealed case

  • Operating Temp Rating

    100.0 deg celsius maximum and -62.0 deg celsius minimum

  • Terminal Type

    tab, solder lug

  • Overall Diameter

    0.623 inches minimum and 0.640 inches maximum

  • Body Height

    0.361 inches minimum and 0.367 inches maximum

  • Contact Load Current Rating

    2.0 amperes resistive load second voltage

  • Temp Sensing Element Type

    internal sensor

  • Thread Series Designator

    unc all threaded stud

  • Contact Voltage Rating In Volts

    30.0 ac at sea level third voltage

  • Contact Load Current Rating

    1.0 amperes resistive load first voltage

  • Media For Which Designed

    gas or liquid

  • Nominal Thread Size

    0.138 inches all threaded stud

  • Nonpile-Up Contact Arrangement

    1 pole, single throw, normally closed, momentary action

  • Contact Load Current Rating

    5.0 amperes resistive load third voltage

  • Contact Voltage Rating In Volts

    125.0 ac at sea level second voltage

  • Contact Load Current Rating

    5.0 amperes resistive load fourth voltage

  • Contact Adjustability

    deactuation point not adjustable and actuation point not adjustable

  • Contact Action Stimulus

    increase

  • Contact Stimulus Rating

    256.00 deactuation point minimum degrees fahrenheit and 272.00 deactuation point maximum degrees fahrenheit and 300.00 actuation point maximum degrees fahrenheit and 288.00 actuation point minimum degrees fahrenheit and 30.00 differential point nominal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...