UPG-6-1-51-802

Circuit Breakers

CIRCUIT BREAKER

UPG-6-1-51-802

5925-01-024-3342

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Terminal Type And Quantity

    2 screw

  • Inclosure Protection Type For Which Designed

    moisture resistant and salt spray proof and shock resistant and vibration resistant

  • Internal Trip Release Configuration

    series trip single location

  • Actuator Position Designation

    at pole one

  • Reset Method

    manual

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Trip Release Characteristic

    time delay single location

  • Iii Storage Type

    general purpose warehouse

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Iii Arc Quenching Method

    magnetic blowout

  • Mounting Surface To Terminal End Distance

    2.032 inches maximum

  • Boss Height

    0.115 inches minimum and 0.145 inches maximum

  • Case Material

    plastic

  • Body Length

    1.985 inches minimum and 2.015 inches maximum

  • Thread Series Designator

    unc

  • Iii Unpackaged Unit Weight

    2.200 ounces

  • Trip Delay Time In Seconds Per Rated Continuous Current

    1.000 minimum at 200 pct and 10.000 maximum at 200 pct single location

  • Nominal Thread Size

    0.138 inches

  • Actuator Function

    trip-reset

  • Manual Actuator Type And Quantity

    1 toggle

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Release Method

    magnetic-hydraulic single location

  • Circuit Protection Type

    overcurrent single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 dc single location

  • Operating Voltage Type And Rating Per Pole In Volts

    65.0 dc single location

  • Maximum Continuous Load Current Rating Per Pole

    8.0 amperes dc single location

  • Thread Quantity Per Inch

    32

  • Iii Special Handling Feature

    magnetic

  • Pole Quantity

    1

  • Iii Fragility Factor

    moderately rugged

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.645 inches minimum and 1.675 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.515 inches minimum and 1.545 inches maximum

  • Body Width

    0.735 inches minimum and 0.765 inches maximum

  • Body Style

    12a single pole type

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...