10 B 612
Filters and Networks
FILTER,RADIO FREQUENCY INTERFERENCE
10 B 612
FILTER,RADIO FREQUENCY INTERFERENCE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Operating Voltage Rating And Type Per Function
115.0 volts ac 3rd radio interference 3rd function
-
Unthreaded Mounting Hole Diameter
0.276 inches minimum and 0.283 inches maximum
-
Power Line Frequency Rating Per Function In Hertz
60.0 2nd radio interference
-
Source Impedance Rating Per Function
50.0 ohms 2nd radio interference
-
Load Impedance Per Function
50.0 ohms 5th radio interference
-
Functional Terminal Type And Quantity
5 threaded stud output 2nd function
-
Power Line Frequency Rating Per Function In Hertz
60.0 3rd radio interference
-
Inclosure Type
hermetically sealed
-
Operating Temp Range
-55.0/+78.0 deg celsius
-
Operating Voltage Rating And Type Per Function
150.0 volts dc 4th radio interference 4th function
-
Operating Voltage Rating And Type Per Function
150.0 volts dc 5th radio interference 5th function
-
Load Impedance Per Function
50.0 ohms 1st radio interference
-
Source Impedance Rating Per Function
50.0 ohms 3rd radio interference
-
Body Width
2.970 inches minimum and 3.030 inches maximum
-
Load Impedance Per Function
50.0 ohms 3rd radio interference
-
Maximum Voltage Drop Per Function
2.6 volts ac 1st radio interference
-
Style Designator
rectangular terminal/terminals on opposite surfaces
-
Source Impedance Rating Per Function
50.0 ohms 1st radio interference
-
Overall Length
11.000 inches maximum
-
Operating Voltage Rating And Type Per Function
115.0 volts ac 2nd radio interference 2nd function
-
Functional Terminal Type And Quantity
5 threaded stud input 1st function
-
Maximum Voltage Drop Per Function
2.6 volts ac 2nd radio interference
-
Maximum Voltage Drop Per Function
2.6 volts ac 3rd radio interference
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.000 inches nominal
-
Maximum Temp Rise
40.0 deg celsius
-
Load Impedance Per Function
50.0 ohms 4th radio interference
-
Mounting Facility Type And Quantity
4 unthreaded hole
-
Power Line Frequency Rating Per Function In Hertz
60.0 1st radio interference
-
Functional Terminal Type And Quantity
2 threaded stud ground 3rd function
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
9.000 inches nominal
-
Overall Height
3.500 inches maximum
-
Source Impedance Rating Per Function
50.0 ohms 4th radio interference
-
Maximum Dielectric Withstanding Dc Voltage
600.0 volts at sea level
-
Load Impedance Per Function
50.0 ohms 2nd radio interference
-
Body Length
8.000 inches maximum
-
Operating Current Rating Per Function In Amps
11.0 1st radio interference
-
Operating Voltage Rating And Type Per Function
115.0 volts ac 1st radio interference 1st function
-
Maximum Voltage Drop Per Function
500.0 millivolts dc 4th radio interference
-
Body Material
metal
-
Source Impedance Rating Per Function
50.0 ohms 5th radio interference
-
Maximum Voltage Drop Per Function
500.0 millivolts dc 5th radio interference
-
Operating Current Rating Per Function In Amps
14.0 4th radio interference
-
Operating Current Rating Per Function In Amps
14.0 5th radio interference
-
Operating Current Rating Per Function In Amps
11.0 2nd radio interference
-
Operating Current Rating Per Function In Amps
11.0 3rd radio interference