GF55450-2
Filters and Networks
FILTER,RADIO FREQUENCY INTERFERENCE
GF55450-2
FILTER,RADIO FREQUENCY INTERFERENCE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Power Line Frequency Rating Per Function In Hertz
60.0 1st radio interference
-
Mounting Facility Screw Thread Series Designator
unc
-
Maximum Temp Rise
45.0 deg celsius
-
Operating Current Rating Per Function In Amps
5.0 1st radio interference
-
Overall Length
4.000 inches nominal
-
Operating Voltage Rating And Type Per Function
120.0 volts ac 2nd radio interference 2nd function
-
Power Line Frequency Rating Per Function In Hertz
60.0 2nd radio interference
-
Source Impedance Rating Per Function
50.0 ohms 2nd radio interference
-
Maximum Voltage Drop Per Function
500.0 millivolts ac 1st radio interference
-
Power Line Frequency Rating Per Function In Hertz
60.0 3rd radio interference
-
Operating Current Rating Per Function In Amps
8.6 3rd radio interference
-
Principal Circuitry Type Per Function
inductance-capacitance 4th radio interference
-
Maximum Dielectric Withstanding Dc Voltage
800.0 volts at sea level
-
Source Impedance Rating Per Function
50.0 ohms 4th radio interference
-
Functional Terminal Type And Quantity
6 threaded stud output 2nd function
-
Load Impedance Per Function
50.0 ohms 2nd radio interference
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
2.380 inches nominal
-
Overall Height
2.000 inches nominal
-
Overall Width
4.500 inches nominal
-
Functional Terminal Type And Quantity
4 threaded stud ground 3rd function
-
Load Impedance Per Function
50.0 ohms 3rd radio interference
-
Style Designator
rectangular terminal/terminals on opposite surfaces
-
Body Length
4.000 inches nominal
-
Mounting Facility Type And Quantity
6 threaded hole
-
Power Line Frequency Rating Per Function In Hertz
60.0 4th radio interference
-
Inclosure Type
hermetically sealed
-
Operating Current Rating Per Function In Amps
8.6 4th radio interference
-
Maximum Voltage Drop Per Function
500.0 millivolts ac 2nd radio interference
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
3.380 inches nominal
-
Maximum Voltage Drop Per Function
500.0 millivolts ac 3rd radio interference
-
Maximum Voltage Drop Per Function
500.0 millivolts ac 4th radio interference
-
Load Impedance Per Function
50.0 ohms 1st radio interference
-
Operating Current Rating Per Function In Amps
5.0 2nd radio interference
-
Operating Temp Range
-55.0/+85.0 deg celsius
-
Operating Voltage Rating And Type Per Function
120.0 volts ac 4th radio interference 4th function
-
Source Impedance Rating Per Function
50.0 ohms 3rd radio interference
-
Operating Voltage Rating And Type Per Function
120.0 volts ac 1st radio interference 1st function
-
Principal Circuitry Type Per Function
inductance-capacitance 1st radio interference
-
Source Impedance Rating Per Function
50.0 ohms 1st radio interference
-
Unpackaged Unit Weight
6.000 ounces
-
Body Width
3.000 inches nominal
-
Nominal Thread Size
0.138 inches
-
Load Impedance Per Function
50.0 ohms 4th radio interference
-
Principal Circuitry Type Per Function
inductance-capacitance 3rd radio interference
-
Operating Voltage Rating And Type Per Function
120.0 volts ac 3rd radio interference 3rd function
-
Body Material
metal
-
Principal Circuitry Type Per Function
inductance-capacitance 2nd radio interference
-
Functional Terminal Type And Quantity
4 threaded stud input 1st function