A01379
Circuit Breakers
CIRCUIT BREAKER
A01379
Racal Communications Systems Ltd
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Body Style
2a single pole type
-
Case Material
plastic
-
Center To Center Distance Between Terminals Parallel To Length
1.515 inches minimum and 1.545 inches maximum
-
Mounting Surface To Terminal End Distance
2.232 inches maximum
-
Operating Voltage Type And Rating Per Pole In Volts
277.0 ac single location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac single location
-
Trip Release Characteristic
time delay all locations
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0
-
Main Contact Tripping Mechanism Type
trip free
-
Manual Actuator Type And Quantity
1 toggle
-
Internal Trip Release Configuration
series trip all locations
-
Bushing Length
0.480 inches minimum and 0.510 inches maximum
-
Body Length
1.985 inches minimum and 2.015 inches maximum
-
Body Width
0.735 inches minimum and 0.765 inches maximum
-
Pole Quantity
1
-
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
-
Thread Quantity Per Inch
32
-
Maximum Continuous Load Current Rating Per Pole
10.0 amperes ac single location
-
Circuit Protection Type
overcurrent all locations
-
Trip Release Method
magnetic-hydraulic third location
-
Reset Method
manual
-
Actuator Function
trip-reset
-
Actuator Position Designation
at pole one
-
Inclosure Protection Type For Which Designed
moisture resistant and salt spray proof and shock resistant and vibration resistant
-
Frequency In Hertz
50.0 or 60.0
-
Nominal Thread Size
0.500 inches
-
Trip Delay Time In Seconds Per Rated Continuous Current
3.000 minimum at 200 pct and 9.000 maximum at 200 pct all locations
-
Thread Series Designator
un
-
Terminal Type And Quantity
2 screw