Technical Characteristics
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 all locations
-
Frequency In Hertz
60.0 all locations or 400.0 all locations
-
Arc Quenching Method
magnetic blowout
-
Body Length
1.562 inches maximum
-
Center To Center Distance Between Terminals Parallel To Length
0.906 inches maximum
-
Thread Series Designator
unef
-
Maximum Continuous Load Current Rating Per Pole
4.0 amperes ac all locations and 4.0 amperes dc all locations
-
Unpackaged Unit Weight
5.400 ounces
-
Specification/Standard Data
81349-mil-c-39019/5 government specification
-
Terminal Type And Quantity
6 wire hook
-
Nonturn Device Diameter
0.235 inches minimum and 0.265 inches maximum
-
Nonturn Device Radius
0.610 inches minimum and 0.640 inches maximum
-
Test Data Document
81349-mil-c-39019 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type
-
Fragility Factor
moderately rugged
-
Special Handling Feature
magnetic
-
Pole Quantity
3
-
Circuit Protection Type
overcurrent all locations
-
Bushing Length
0.332 inches minimum and 0.380 inches maximum
-
Reset Method
manual
-
Center To Center Distance Between Terminals Parallel To Width
0.594 inches minimum and 0.656 inches maximum
-
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
-
~1
data on certain environmental and performanc
-
Main Contact Tripping Mechanism Type
trip free
-
Body Width
1.937 inches maximum
-
Inclosure Protection Type For Which Designed
shockproof and fungus resistant and salt spray proof and vibrationproof and moisture resistant and hermetically sealed
-
Manual Actuator Type And Quantity
1 toggle
-
Case Material
metal
-
Body Style
multipole-single actuator type
-
Nonturn Device Location
at 3 oclock and at 9 oclock
-
Actuator Position Designation
at pole two
-
Trip Release Method
magnetic all locations
-
Thread Quantity Per Inch
32
-
Nominal Thread Size
0.375 inches
-
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations and 50.0 dc all locations
-
Thread Pitch Diameters
+0.3503/+0.3537 inches
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
300.0 ac all locations and 500.0 dc all locations
-
Internal Trip Release Configuration
series trip all locations
-
Mounting Surface To Terminal End Distance
1.828 inches maximum
-
Actuator Function
trip-reset
-
Trip Release Characteristic
time delay all locations
-
Storage Type
general purpose warehouse
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.055 minimum at 200 pct all locations and 0.950 maximum at 200 pct all locations