790082-PIECE 140
Filters and Networks
FILTER,RADIO FREQUENCY INTERFERENCE
790082-PIECE 140
FILTER,RADIO FREQUENCY INTERFERENCE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Maximum Dielectric Withstanding Dc Voltage
600.0 volts at sea level
-
Load Impedance Per Function
50.0 ohms 2nd radio interference
-
Maximum Voltage Drop Per Function
2.5 volts ac 1st radio interference
-
Maximum Voltage Drop Per Function
2.5 volts ac 2nd radio interference
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
2.000 inches nominal
-
Operating Voltage Rating And Type Per Function
115.0 volts ac 1st radio interference 1st function
-
Body Material
metal
-
Principal Circuitry Type Per Function
inductance-capacitance 2nd radio interference
-
Operating Current Rating Per Function In Amps
14.3 1st radio interference
-
Load Impedance Per Function
50.0 ohms 3rd radio interference
-
Style Designator
rectangular terminal/terminals on opposite surfaces
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
7.875 inches nominal
-
Source Impedance Rating Per Function
50.0 ohms 1st radio interference
-
Body Length
7.000 inches maximum
-
Functional Terminal Type And Quantity
3 threaded stud output 2nd function
-
Operating Current Rating Per Function In Amps
14.3 2nd radio interference
-
Unpackaged Unit Weight
6.000 pounds
-
Operating Voltage Rating And Type Per Function
115.0 volts ac 2nd radio interference 2nd function
-
Operating Current Rating Per Function In Amps
14.3 3rd radio interference
-
Body Width
2.720 inches minimum and 2.780 inches maximum
-
Overall Length
9.000 inches maximum
-
Mounting Facility Type And Quantity
4 unthreaded hole
-
Principal Circuitry Type Per Function
inductance-capacitance 3rd radio interference
-
Power Line Frequency Rating Per Function In Hertz
60.0 1st radio interference
-
Maximum Temp Rise
45.0 deg celsius
-
Overall Height
2.000 inches maximum
-
Functional Terminal Type And Quantity
2 threaded stud ground 3rd function
-
Operating Voltage Rating And Type Per Function
115.0 volts ac 3rd radio interference 3rd function
-
Power Line Frequency Rating Per Function In Hertz
60.0 2nd radio interference
-
Source Impedance Rating Per Function
50.0 ohms 2nd radio interference
-
Functional Terminal Type And Quantity
3 threaded stud input 1st function
-
Power Line Frequency Rating Per Function In Hertz
60.0 3rd radio interference
-
Inclosure Type
hermetically sealed
-
Unthreaded Mounting Hole Diameter
0.218 inches minimum and 0.224 inches maximum
-
Operating Temp Range
-55.0/+78.0 deg celsius
-
Maximum Voltage Drop Per Function
2.5 volts ac 3rd radio interference
-
Load Impedance Per Function
50.0 ohms 1st radio interference
-
Source Impedance Rating Per Function
50.0 ohms 3rd radio interference
-
Principal Circuitry Type Per Function
inductance-capacitance 1st radio interference