20TC2-ED-30
Circuit Breakers
CIRCUIT BREAKER
20TC2-ED-30
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Mounting Surface To Terminal End Distance
1.624 inches nominal
-
Thread Series Designator
unc
-
Reset Method
manual
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 single location
-
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac single location and 30.0 dc single location
-
Body Length
1.870 inches nominal
-
Body Width
0.750 inches maximum
-
Case Material
plastic
-
Trip Delay Time In Seconds Per Rated Continuous Current
10.000 minimum at 200 pct single location and 130.000 maximum at 200 pct single location
-
Actuator Position Designation
at pole one
-
Maximum Continuous Load Current Rating Per Pole
30.0 amperes ac single location and 30.0 amperes dc single location
-
Actuator Function
trip-reset
-
Terminal Type And Quantity
2 screw
-
Mounting Facility Type And Quantity
2 threaded hole
-
Thread Quantity Per Inch
32
-
Circuit Protection Type
overcurrent single location
-
Trip Release Method
thermal single location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac single location and 2000.0 dc single location
-
Pole Quantity
1
-
Manual Actuator Type And Quantity
1 toggle
-
Center To Center Distance Between Terminals Parallel To Length
0.688 inches nominal
-
Internal Trip Release Configuration
series trip single location
-
Nominal Thread Size
0.138 inches
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.620 inches nominal
-
Trip Release Characteristic
time delay single location
-
Trip Release Ambient Temp Rating
25.0 deg celsius nominal single location
-
Main Contact Tripping Mechanism Type
trip free
-
Frequency In Hertz
400.0 single location
-
Body Style
single pole type