CJ3-G3-U-115-240-60H-3

Circuit Breakers

CIRCUIT BREAKER

CJ3-G3-U-115-240-60H-3

5925-01-026-9650

5925 - Circuit Breakers

U S Dept Of Transportation

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Style

    11b multipole-single actuator type

  • Body Length

    6.990 inches minimum and

  • Body Width

    4.510 inches maximum

  • Body Height

    2.677 inches minimum and

  • Center To Center Distance Between Terminals Parallel To Length

    6.115 inches minimum and

  • Center To Center Distance Between Terminals Parallel To Length

    6.135 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    1.510 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    4.369 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.490 inches minimum and

  • Iii Fragility Factor

    moderately rugged

  • Boss Height

    0.208 inches minimum and

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Maximum Continuous Load Current Rating Per Pole

    115.0 amperes ac all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    10000.0 ac all locations

  • Circuit Protection Type

    overcurrent all locations

  • Reset Method

    manual

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.200 minimum at 200 pct and

  • Trip Delay Time In Seconds Per Rated Continuous Current

    1.800 maximum at 200 pct all locations

  • Frequency In Hertz

    60.0 all locations

  • Terminal Type And Quantity

    6 compression

  • Body Length

    7.010 inches maximum

  • Body Width

    4.490 inches minimum and

  • Body Height

    2.697 inches maximum

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Width

    1.490 inches minimum and

  • Unthreaded Mounting Hole Diameter

    0.250 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    4.349 inches minimum and

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.510 inches maximum

  • Iii End Item Identification

    general application electronics (gen-ap-e)

  • Boss Height

    0.228 inches maximum

  • Pole Quantity

    3

  • Iii Arc Quenching Method

    magnetic blowout

  • Iii Storage Type

    general purpose warehouse

  • Trip Release Method

    magnetic-hydraulic all locations

  • Trip Release Characteristic

    time delay all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Position Designation

    at pole two

  • Inclosure Protection Type For Which Designed

    dustproof

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...