AP112-R-252-8

Circuit Breakers

CIRCUIT BREAKER

AP112-R-252-8

5925-01-027-8133

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Center To Center Distance Between Terminals Parallel To Length

    0.875 inches nominal

  • Body Style

    multipole-single actuator type

  • Case Material

    metal

  • Manual Actuator Type And Quantity

    1 toggle

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 all locations

  • Arc Quenching Method

    magnetic blowout

  • Bushing Length

    0.375 inches nominal

  • Inclosure Protection Type For Which Designed

    fungus resistant and explosion resistant and hermetically sealed

  • Switch Location And Position Designation

    internal at each pole

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac all locations

  • Body Width

    1.872 inches nominal

  • Frequency In Hertz

    400.0 all locations

  • Thread Series Designator

    unef

  • Terminal Type And Quantity

    6 wire hook

  • Switch Current Rating And Type In Amps

    1.0 ac and 0.5 dc

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    300.0 ac all locations

  • Fragility Factor

    moderately rugged

  • Switch Terminal Type

    tab, solder lug

  • Special Handling Feature

    magnetic

  • Pole Quantity

    3

  • Switch Contact Arrangement

    single pole, double throw

  • Body Length

    1.495 inches nominal

  • Actuator Position Designation

    at pole two

  • Trip Release Method

    magnetic all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • Thread Quantity Per Inch

    32

  • Nominal Thread Size

    0.375 inches

  • Thread Pitch Diameters

    +0.3503/+0.3537 inches

  • Switch Voltage Rating And Type In Volts

    125.0 ac and 50.0 dc

  • Internal Trip Release Configuration

    series trip all locations

  • Auxiliary Switch Function And Quantity

    3 alarm

  • Mounting Surface To Terminal End Distance

    1.678 inches nominal

  • Test Data Document

    56232-338362 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)

  • Actuator Function

    trip-reset

  • Center To Center Distance Between Terminals Parallel To Width

    0.625 inches nominal

  • Trip Release Characteristic

    time delay all locations

  • Storage Type

    general purpose warehouse

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.055 minimum at 200 pct all locations and 0.950 maximum at 200 pct all locations

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Reset Method

    manual

  • Circuit Protection Type

    overcurrent all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...