HE2-B3-21

Circuit Breakers

CIRCUIT BREAKER

HE2-B3-21

5925-01-028-5188

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Style

    multipole-single actuator type

  • Bushing Length

    0.365 inches minimum and 0.385 inches maximum

  • Body Length

    1.552 inches minimum and 1.572 inches maximum

  • Body Width

    1.271 inches minimum and 1.291 inches maximum

  • Case Material

    metal

  • Center To Center Distance Between Terminals Parallel To Length

    0.865 inches minimum and 0.885 inches maximum

  • Fragility Factor

    moderately rugged

  • Mounting Surface To Terminal End Distance

    1.690 inches minimum and 1.710 inches maximum

  • Arc Quenching Method

    magnetic blowout

  • Trip Release Method

    magnetic-hydraulic

  • Trip Release Characteristic

    time delay

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Position Designation

    between pole one and two

  • Nominal Thread Size

    0.375 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.300 minimum at 150 pct and 2.000 maximum at 150 pct and 0.100 minimum at 200 pct and 0.700 maximum at 200 pct and 0.030 minimum at 300 pct and 0.200 maximum at 300 pct

  • Inclosure Protection Type For Which Designed

    dustproof and explosion proof and fungus resistant and moisture resistant

  • Thread Series Designator

    unef

  • Center To Center Distance Between Terminals Parallel To Width

    0.615 inches minimum and 0.635 inches maximum

  • Pole Quantity

    2

  • Mounting Facility Type And Quantity

    thd bushing w/panel seal

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    1.0 amperes dc

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    500.0 dc

  • Circuit Protection Type

    overcurrent

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip

  • Terminal Type And Quantity

    4 wire hook

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...