714-3233-170
Resistors
RESISTOR,THERMAL
714-3233-170
RESISTOR,THERMAL
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Temp Points For Resistance Readings At Zero Power
-25.0 deg celsius 2nd resistance-temperature point
-
Zero Power Resistance At Specified Temp
1.4 megohms 4th resistance-temperature point
-
Body Outside Diameter
0.043 inches nominal
-
Zero Power Resistance At Specified Temp
7.5 kilohms 2nd resistance-temperature point
-
Zero Power Resistance At Specified Temp
340.0 megohms 6th resistance-temperature point
-
Resistance Tolerance At A Specified Temp In Percent
-15.0/+15.0 all resistance-temperature points
-
Temp Points For Resistance Readings At Zero Power
300.0 deg celsius 6th resistance-temperature point
-
Zero Power Resistance At Specified Temp
850.0 ohms 1st resistance-temperature point
-
Terminal Length
0.500 inches nominal
-
Temp Points For Resistance Readings At Zero Power
100.0 deg celsius 4th resistance-temperature point
-
Inclosure Type
encapsulated
-
Power Dissipation Constant In Milliwatts Per Deg Celsius
0.35
-
Zero Power Resistance Tolerance In Percent At Reference Temp
-20.0/+20.0
-
Style Designator
sealed or coated bead
-
Zero Power Temp Coefficient Of Resistance In Percent Per Deg Celsius
-5.40
-
Reliability Indicator
not established
-
Temp Points For Resistance Readings At Zero Power
200.0 deg celsius 5th resistance-temperature point
-
Terminal Type And Quantity
2 wire lead
-
Ambient Temp At Full Rated Power
25.0 deg celsius
-
Zero Power Resistance At Specified Temp
16.0 kilohms 3rd resistance-temperature point
-
Terminal Diameter
0.004 inches nominal
-
Test Data Document
13499-714-3233-170 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
-
Zero Power Resistance
5.000 megohms
-
Thermal Time Constant In Seconds
8.0
-
Zero Power Resistance At Specified Temp
115.0 megohms 5th resistance-temperature point
-
Maximum Operating Temp
150.0 deg celsius
-
Temp Points For Resistance Readings At Zero Power
50.0 deg celsius 3rd resistance-temperature point
-
Temp Points For Resistance Readings At Zero Power
-40.0 deg celsius 1st resistance-temperature point