4411
Filters and Networks
FILTER,BAND PASS
4411
Electronic Precision Components Corp
FILTER,BAND PASS
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Specified Frequencies Of Discrimination Per Function
25.90 kilohertz 1st band pass and 26.10 kilohertz 1st band pass and 22.80 kilohertz 1st band pass and 28.40 kilohertz 1st band pass
-
Insertion Loss At Reference Frequency Per Function In Decibels
3.0 1st band pass
-
Frequency Band Width Per Function
37.90 kilohertz 6th band pass and 38.10 kilohertz 6th band pass
-
Specified Frequencies Of Discrimination Per Function
30.70 kilohertz 3rd band pass and 28.40 kilohertz 3rd band pass and 30.90 kilohertz 3rd band pass and 33.20 kilohertz 3rd band pass
-
Discrimination At Specified Frequencies Per Function In Decibels
3.0 maximum 3rd band pass and 30.0 minimum 3rd band pass and 3.0 maximum 3rd band pass and 30.0 minimum 3rd band pass
-
Load Impedance Per Function
50.0 ohms 1st band pass
-
Discrimination At Specified Frequencies Per Function In Decibels
3.0 maximum 2nd band pass and 3.0 maximum 2nd band pass and 30.0 minimum 2nd band pass and 30.0 minimum 2nd band pass
-
Specified Frequencies Of Discrimination Per Function
28.30 kilohertz 2nd band pass and 28.50 kilohertz 2nd band pass and 26.40 kilohertz 2nd band pass and 30.80 kilohertz 2nd band pass
-
Body Length
6.000 inches nominal
-
Reference Frequency Per Function
33.2 single radio interference hertz
-
Frequency Band Width Per Function
25.90 kilohertz 1st band pass and 26.10 kilohertz 1st band pass
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
5.000 inches nominal
-
Inclosure Type
encased
-
Mounting Facility Screw Thread Series Designator
unc
-
Nominal Thread Size
0.112 inches
-
Reference Frequency Per Function
30.8 single radio interference two phase to three phase
-
Specified Frequencies Of Discrimination Per Function
33.20 kilohertz 5th band pass and 35.50 kilohertz 5th band pass and 35.70 kilohertz 5th band pass and 38.00 kilohertz 5th band pass
-
Load Impedance Per Function
50.0 ohms 5th band pass
-
Functional Terminal Type And Quantity
6 pin input-output/ground 3rd function
-
Source Impedance Rating Per Function
1.0 ohms 4th band pass
-
Body Width
1.750 inches nominal
-
Frequency Band Width Per Function
28.30 kilohertz 2nd band pass and 28.50 kilohertz 2nd band pass
-
Functional Terminal Type And Quantity
1 pin output 2nd function
-
Source Impedance Rating Per Function
1.0 ohms 5th band pass
-
Load Impedance Per Function
50.0 ohms 6th band pass
-
Source Impedance Rating Per Function
1.0 ohms 6th band pass
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.250 inches nominal
-
Insertion Loss At Reference Frequency Per Function In Decibels
3.0 2nd band pass
-
Frequency Band Width Per Function
33.10 kilohertz 4th band pass and 33.30 kilohertz 4th band pass
-
Load Impedance Per Function
50.0 ohms 2nd band pass
-
Mounting Facility Type And Quantity
12 threaded hole
-
Body Material
metal
-
Reference Frequency Per Function
35.6 single radio interference three phase to two phase
-
Insertion Loss At Reference Frequency Per Function In Decibels
3.0 4th band pass
-
Source Impedance Rating Per Function
1.0 ohms 1st band pass
-
Style Designator
rectangular terminal/terminals on one surface
-
Reference Frequency Per Function
28.4 single radio interference two phase to two phase
-
Discrimination At Specified Frequencies Per Function In Decibels
3.0 maximum 6th band pass and 3.0 maximum 6th band pass and 30.0 minimum 6th band pass and 30.0 minimum 6th band pass
-
Load Impedance Per Function
50.0 ohms 4th band pass
-
Discrimination At Specified Frequencies Per Function In Decibels
30.0 minimum 1st band pass and 3.0 maximum 1st band pass and 3.0 maximum 1st band pass and 30.0 minimum 1st band pass
-
Source Impedance Rating Per Function
1.0 ohms 2nd band pass
-
Insertion Loss At Reference Frequency Per Function In Decibels
3.0 5th band pass
-
Insertion Loss At Reference Frequency Per Function In Decibels
3.0 6th band pass
-
Source Impedance Rating Per Function
1.0 ohms 3rd band pass
-
Frequency Band Width Per Function
30.70 kilohertz 3rd band pass and 30.90 kilohertz 3rd band pass
-
Body Height
0.868 inches nominal
-
Frequency Band Width Per Function
35.50 kilohertz 5th band pass and 35.70 kilohertz 5th band pass
-
Functional Terminal Type And Quantity
1 pin input 1st function
-
Specified Frequencies Of Discrimination Per Function
35.60 kilohertz 6th band pass and 38.10 kilohertz 6th band pass and 37.90 kilohertz 6th band pass and 43.00 kilohertz 6th band pass
-
Overall Height
0.993 inches nominal
-
Insertion Loss At Reference Frequency Per Function In Decibels
3.0 3rd band pass
-
Reference Frequency Per Function
26.0 single radio interference pulses per second
-
Body Surface Treatment
tin
-
Discrimination At Specified Frequencies Per Function In Decibels
3.0 maximum 5th band pass and 3.0 maximum 5th band pass and 30.0 minimum 5th band pass and 30.0 minimum 5th band pass
-
Specified Frequencies Of Discrimination Per Function
33.10 kilohertz 4th band pass and 30.80 kilohertz 4th band pass and 33.30 kilohertz 4th band pass and 35.60 kilohertz 4th band pass
-
Load Impedance Per Function
50.0 ohms 3rd band pass
-
Reference Frequency Per Function
38.0 single radio interference gigahertz
-
Discrimination At Specified Frequencies Per Function In Decibels
30.0 minimum 4th band pass and 3.0 maximum 4th band pass and 3.0 maximum 4th band pass and 30.0 minimum 4th band pass