S2217
Filters and Networks
FILTER,BAND PASS
S2217
FILTER,BAND PASS
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Body Height
1.406 inches nominal
-
Operating Temp Range
+10.0/+65.0 deg celsius
-
Functional Terminal Type And Quantity
1 connector, receptacle output 2nd function
-
Input Impedance Per Function W/Load
10.0 ohms 2nd band pass
-
Frequency Band Width Per Function
2.975 gigahertz 1st band pass and 3.025 gigahertz 1st band pass
-
Specified Frequencies Of Discrimination Per Function
3.025 gigahertz 2nd band pass and 2.68 gigahertz 2nd band pass and 2.975 gigahertz 2nd band pass and 3.32 gigahertz 2nd band pass
-
Input Impedance Per Function W/Load
10.0 ohms 1st band pass
-
Discrimination At Specified Frequencies Per Function In Decibels
3.0 maximum 1st band pass and 3.0 maximum 1st band pass and 70.0 minimum 1st band pass and 70.0 minimum 1st band pass
-
Output Impedance Per Function W/Source Across Input
10.0 ohms 2nd band pass
-
Mounting Facility Screw Thread Series Designator
unc
-
Output Impedance Per Function W/Source Across Input
10.0 ohms 1st band pass
-
Overall Length
2.406 inches nominal
-
Nominal Thread Size
0.138 inches
-
Body Width
1.406 inches nominal
-
Voltage Standing Wave Ratio Per Function
2.1 2nd band pass
-
Discrimination At Specified Frequencies Per Function In Decibels
70.0 minimum 2nd band pass and 3.0 maximum 2nd band pass and 3.0 maximum 2nd band pass and 70.0 minimum 2nd band pass
-
Style Designator
rectangular terminal/terminals on opposite surfaces
-
Specified Frequencies Of Discrimination Per Function
3.025 gigahertz 1st band pass and 2.68 gigahertz 1st band pass and 2.975 gigahertz 1st band pass and 3.32 gigahertz 1st band pass
-
Voltage Standing Wave Ratio Per Function
2.1 1st band pass
-
Body Length
1.406 inches nominal
-
Functional Terminal Type And Quantity
1 connector, receptacle input 1st function
-
Mounting Facility Type And Quantity
4 threaded hole
-
Reference Frequency Per Function
3.0 composition b grade a two phase to two phase
-
Special Features
2 coil terminals and 2 heater terminals in addition to input and output terminals
-
Insertion Loss At Reference Frequency Per Function In Decibels
3.5 2nd band pass
-
Insertion Loss At Reference Frequency Per Function In Decibels
3.5 1st band pass
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.125 inches nominal
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.125 inches nominal
-
Inclosure Type
encased
-
Reference Frequency Per Function
3.0 composition b grade a pulses per second
-
Frequency Band Width Per Function
2.975 gigahertz 2nd band pass and 3.025 gigahertz 2nd band pass