KCD4A

Relays and Solenoids

RELAY,ELECTROMAGNETIC

KCD4A

5945-01-030-9865

5945 - Relays and Solenoids

Leach Corp

RELAY,ELECTROMAGNETIC

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Main Contact Maximum Voltage Rating In Volts

    115.0 ac and 28.0 dc

  • Main Contact Load Current Rating At Maximum Rated Voltage

    5.0 amperes ac lamp load and 5.0 amperes dc lamp load

  • Purpose For Which Designed

    general

  • Overall Width

    1.025 inches maximum

  • Operating Voltage Rating And Type At Specified Temp

    28.0 volts dc 25 deg celsius single winding

  • Coil Quantity

    1

  • Winding Dc Resistance Rating

    290.0 ohms nominal single winding

  • Fragility Factor

    moderately rugged

  • Main Contact Load Current Rating At Maximum Rated Voltage

    12.0 amperes ac inductive load and 12.0 amperes dc inductive load

  • Overall Height

    1.280 inches maximum

  • Storage Type

    general purpose warehouse

  • Time Delay

    0.015 seconds maximum fixed operate and release time

  • Cubic Measure

    2.254 cubic inches

  • Environmental Protection

    hermetic

  • Mounting Slot Width

    0.150 inches nominal single mounting facility

  • Arc Quenching Method

    air

  • Winding Quantity

    1

  • Overall Length

    1.718 inches maximum

  • Main Contact Load Current Rating At Maximum Rated Voltage

    25.0 amperes ac resistive load and 25.0 amperes dc resistive load

  • Mounting Facility Type And Quantity

    3 slotted hole single mounting facility

  • Center To Center Distance Between Mounting Facilities Parallel To The Altitude Of An Isosceles Triangle

    1.396 inches minimum single mounting facility and 1.446 inches maximum single mounting facility

  • Case Material

    metal

  • Features Provided

    polarized

  • Terminal Type And Quantity

    11 pin all functions

  • Mounting Facility Pattern

    triangle single mounting facility

  • Main Contact Load Current Rating At Maximum Rated Voltage

    10.0 amperes ac motor load and 10.0 amperes dc motor load

  • Nonpile-Up Main Contact Arrangement

    3 pole, double throw, one position momentary

  • Duty Type

    continuous

  • Center To Center Distance Between Mounting Facilities Parallel To Width

    0.625 inches nominal single mounting facility

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...