860028-42

Circuit Breakers

CIRCUIT BREAKER

860028-42

5925-01-031-9916

5925 - Circuit Breakers

Litton Systems Inc. Div Navigation

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 single location

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc single location

  • Body Style

    single pole type

  • Body Width

    0.625 inches maximum

  • Thread Series Designator

    unef

  • Mounting Surface To Terminal End Distance

    1.700 inches maximum

  • Bushing Length

    0.330 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    0.910 inches maximum

  • Fragility Factor

    moderately rugged

  • Trip Release Method

    magnetic single location

  • Terminal Type And Quantity

    2 wire hook

  • Reset Method

    manual

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Body Length

    1.562 inches maximum

  • Arc Quenching Method

    magnetic blowout

  • Main Contact Tripping Mechanism Type

    trip free

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    500.0 dc single location

  • Trip Release Characteristic

    time delay single location

  • Internal Trip Release Configuration

    series trip single location

  • Manual Actuator Type And Quantity

    1 toggle

  • Case Material

    metal

  • Pole Quantity

    1

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Test Data Document

    13973-860028-42 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.800 minimum at 200 pct single location and 4.000 maximum at 200 pct single location

  • Circuit Protection Type

    overcurrent single location

  • Thread Quantity Per Inch

    32

  • Nominal Thread Size

    0.375 inches

  • Thread Pitch Diameters

    +0.3503/+0.3537 inches

  • Actuator Function

    trip-reset

  • Maximum Continuous Load Current Rating Per Pole

    35.0 amperes dc single location

  • Storage Type

    general purpose warehouse

  • Unpackaged Unit Weight

    2.100 ounces

  • Actuator Position Designation

    at pole one

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...