2760396-3
Circuit Breakers
CIRCUIT BREAKER
2760396-3
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Body Style
multipole-multiple actuator type
-
Body Length
2.500 inches nominal
-
Body Width
2.250 inches nominal
-
Center To Center Distance Between Terminals Parallel To Length
1.938 inches nominal
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.062 inches nominal
-
Boss Height
0.140 inches nominal
-
Mounting Surface To Terminal End Distance
2.471 inches nominal
-
Pole Quantity
3
-
Mounting Facility Type And Quantity
6 threaded hole
-
Maximum Continuous Load Current Rating Per Pole
50.0 amperes ac
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac
-
Trip Release Characteristic
time delay
-
Reset Method
manual
-
Main Contact Tripping Mechanism Type
trip free
-
Trip Delay Time In Seconds Per Rated Continuous Current
10.000 nominal at 600 pct
-
Inclosure Protection Type For Which Designed
explosion resistant
-
Frequency In Hertz
400.0
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.750 inches nominal
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac
-
Manual Actuator Type And Quantity
3 toggle
-
Nominal Thread Size
0.138 inches
-
Thread Series Designator
unc
-
Terminal Type And Quantity
6 threaded stud
-
Reference Number Differentiating Characteristics
navord od42046