CD2-Z106-2

Circuit Breakers

CIRCUIT BREAKER

CD2-Z106-2

5925-01-033-1197

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Circuit Protection Type

    overcurrent all locations

  • Maximum Continuous Load Current Rating Per Pole

    50.0 amperes ac all locations

  • Inclosure Protection Type For Which Designed

    dustproof

  • Mounting Facility Type And Quantity

    4 threaded hole and 4 slot

  • Pole Quantity

    2

  • Thread Series Designator

    unc

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Storage Type

    general purpose warehouse

  • Trip Release Ambient Temp Rating

    40.0 deg celsius nominal all locations

  • Actuator Function

    trip-reset

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.016 inches minimum and 1.036 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    3.515 inches minimum and 3.579 inches maximum

  • Boss Height

    0.209 inches minimum and 0.229 inches maximum

  • Thread Quantity Per Inch

    32

  • Body Style

    multipole-multiple actuator type

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Case Material

    plastic

  • External Actuator Linkage Arrangement

    one and two linked

  • Terminal Type And Quantity

    4 threaded stud

  • Mounting Slot Width

    0.164 inches nominal

  • Manual Actuator Type And Quantity

    2 toggle

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac all locations

  • Center To Center Distance Between Terminals Parallel To Width

    1.016 inches minimum and 1.036 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.718 inches minimum and 2.782 inches maximum

  • Body Width

    2.038 inches minimum and 2.102 inches maximum

  • Arc Quenching Method

    magnetic blowout

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    15000.0 ac all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Body Length

    5.768 inches minimum and 5.832 inches maximum

  • Frequency In Hertz

    60.0 all locations

  • Nominal Thread Size

    0.138 inches

  • Mounting Surface To Terminal End Distance

    3.172 inches minimum and 3.296 inches maximum

  • Trip Release Method

    thermal-magnetic all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...