X1163C10

Circuit Breakers

CIRCUIT BREAKER

X1163C10

5925-01-033-5959

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Length

    5.240 inches minimum and 5.260 inches maximum

  • Case Material

    plastic

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.974 inches minimum and 0.994 inches maximum

  • Boss Height

    0.208 inches minimum and 0.228 inches maximum

  • Body Style

    9a single pole type

  • Body Width

    1.490 inches minimum and 1.510 inches maximum

  • Body Height

    2.677 inches minimum and 2.697 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    4.349 inches minimum and 4.369 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    3.052 inches minimum and 3.072 inches maximum

  • Fragility Factor

    moderately rugged

  • Pole Quantity

    1

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac single location

  • Circuit Protection Type

    overcurrent single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Trip Delay Time In Seconds Per Rated Continuous Current

    35.000 minimum at 200 pct single location and 110.000 maximum at 200 pct

  • Inclosure Protection Type For Which Designed

    dustproof and fungus proof

  • Terminal Type And Quantity

    2 compression

  • Thread Series Designator

    unc

  • Frequency In Hertz

    60.0 single location

  • Nominal Thread Size

    0.138 inches

  • Internal Trip Release Configuration

    series trip single location

  • Actuator Position Designation

    at pole one

  • Trip Release Characteristic

    time delay single location

  • Trip Release Method

    magnetic-hydraulic single location

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes ac single location

  • Thread Quantity Per Inch

    32

  • Storage Type

    general purpose warehouse

  • Arc Quenching Method

    magnetic blowout

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...