Technical Characteristics

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac all locations and 240.0 ac all locations

  • Special Handling Feature

    magnetic

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    2

  • Terminal Type And Quantity

    5 wire hook

  • Reset Method

    manual

  • Maximum Continuous Load Current Rating Per Pole

    8.5 amperes ac first location and 17.0 amperes ac second location

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Trip Delay Time In Seconds Per Rated Continuous Current

    1.000 maximum at 200 pct first location

  • Thread Pitch Diameters

    +0.3503/+0.3537 inches

  • Nominal Thread Size

    0.375 inches

  • Thread Quantity Per Inch

    32

  • Trip Release Method

    magnetic all locations

  • Mounting Surface To Terminal End Distance

    1.780 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    0.860 inches minimum and 0.890 inches maximum

  • Nonturn Device Location

    at 3 oclock and at 9 oclock

  • Body Style

    multipole-single actuator type

  • Case Material

    metal

  • Internal Trip Release Configuration

    series trip second location

  • Manual Actuator Type And Quantity

    1 toggle

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.090 minimum at 200 pct first location and 0.090 minimum at 200 pct second location and 0.600 maximum at 200 pct second location

  • Maximum Continuous Load Current Rating Per Pole

    17.0 amperes ac first location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    500.0 ac all locations and 300.0 ac all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 all locations

  • Arc Quenching Method

    magnetic blowout

  • Unpackaged Unit Weight

    3.600 ounces

  • Fragility Factor

    moderately rugged

  • Frequency In Hertz

    47.0 all locations or 420.0 all locations

  • Body Length

    1.562 inches maximum

  • Internal Trip Release Configuration

    shunt trip first location

  • Center To Center Distance Between Terminals Parallel To Width

    0.610 inches minimum and 0.640 inches maximum

  • Thread Series Designator

    unef

  • Body Width

    1.281 inches maximum

  • Inclosure Protection Type For Which Designed

    hermetically sealed and shock resistant and vibration resistant

  • Bushing Length

    0.380 inches maximum

  • Nonturn Device Diameter

    0.235 inches minimum and 0.265 inches maximum

  • Nonturn Device Radius

    0.610 inches minimum and 0.640 inches maximum

  • Nonturn Device Length

    0.130 inches nominal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...