3XAM1516HKMG3-12.5-250-2-60

Circuit Breakers

CIRCUIT BREAKER

3XAM1516HKMG3-12.5-250-2-60

5925-01-034-7502

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Frequency In Hertz

    60.0

  • Switch Current Rating And Type In Amps

    2.5 ac

  • Inclosure Protection Type For Which Designed

    dustproof and fungus proof

  • Nominal Thread Size

    0.138 inches

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Actuator Function

    trip-reset

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Trip Release Characteristic

    time delay all locations

  • Trip Release Method

    magnetic-hydraulic all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac all locations

  • Maximum Continuous Load Current Rating Per Pole

    12.5 amperes ac all locations

  • Thread Quantity Per Inch

    32

  • Storage Type

    general purpose warehouse

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Arc Quenching Method

    magnetic blowout

  • Pole Quantity

    3

  • Mounting Surface To Terminal End Distance

    3.239 inches nominal

  • Boss Height

    0.146 inches minimum and 0.166 inches maximum

  • Fragility Factor

    moderately rugged

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.021 inches minimum and 1.041 inches maximum

  • Switch Contact Arrangement

    single pole, double throw

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.740 inches minimum and 2.760 inches maximum

  • Body Length

    3.709 inches minimum and 3.729 inches maximum

  • Terminal Type And Quantity

    6 threaded stud

  • Thread Series Designator

    unc

  • Switch Voltage Rating And Type In Volts

    250.0 ac

  • Switch Terminal Type

    tab, solder lug

  • Trip Delay Time In Seconds Per Rated Continuous Current

    5.500 minimum at 200 pct and 20.000 maximum at 200 pct all locations

  • Switch Location And Position Designation

    internal at pole one

  • Internal Trip Release Configuration

    series trip all locations

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Actuator Position Designation

    at each pole

  • Manual Actuator Type And Quantity

    3 toggle

  • Reset Method

    manual

  • Circuit Protection Type

    overcurrent all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1500.0 ac all locations

  • Center To Center Distance Between Terminals Parallel To Width

    1.021 inches minimum and 1.041 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    3.053 inches minimum and 3.072 inches maximum

  • Case Material

    plastic

  • Body Width

    3.042 inches minimum and 3.062 inches maximum

  • Body Style

    8c multipole-multiple actuator type

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...