1227782
Filters and Networks
FILTER,RADIO FREQUENCY INTERFERENCE
1227782
FILTER,RADIO FREQUENCY INTERFERENCE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Operating Voltage Rating And Type Per Function
50.0 volts dc 4th radio interference 4th function
-
Operating Voltage Rating And Type Per Function
50.0 volts dc 5th radio interference 5th function
-
Load Impedance Per Function
50.0 ohms 4th radio interference
-
Output Terminal Identification
ms3124-e18-11s
-
Mounting Facility Type And Quantity
4 unthreaded hole
-
Input Terminal Manufacturer Code
96906
-
Source Impedance Rating Per Function
50.0 ohms 1st radio interference
-
Output Terminal Manufacturer Code
96906
-
Operating Voltage Rating And Type Per Function
50.0 volts dc 3rd radio interference 3rd function
-
Overall Length
9.500 inches maximum
-
Style Designator
rectangular terminal/terminals on opposite surfaces
-
Load Impedance Per Function
50.0 ohms 3rd radio interference
-
Operating Current Rating Per Function In Amps
50.0 2nd radio interference
-
Operating Current Rating Per Function In Amps
50.0 1st radio interference
-
Operating Voltage Rating And Type Per Function
50.0 volts dc 2nd radio interference 2nd function
-
Maximum Voltage Drop Per Function
500.0 millivolts dc 5th radio interference
-
Functional Terminal Type And Quantity
1 connector, receptacle input 1st function
-
Source Impedance Rating Per Function
50.0 ohms 5th radio interference
-
Body Material
metal
-
Maximum Voltage Drop Per Function
500.0 millivolts dc 4th radio interference
-
Body Length
8.100 inches maximum
-
Maximum Voltage Drop Per Function
500.0 millivolts dc 3rd radio interference
-
Body Width
5.500 inches maximum
-
Maximum Voltage Drop Per Function
500.0 millivolts dc 2nd radio interference
-
Input Terminal Identification
ms3124-e20-16p
-
Operating Voltage Rating And Type Per Function
50.0 volts dc 1st radio interference 1st function
-
Operating Current Rating Per Function In Amps
5.0 3rd radio interference
-
Inclosure Type
encased
-
Operating Current Rating Per Function In Amps
5.0 4th radio interference
-
Operating Current Rating Per Function In Amps
5.0 5th radio interference
-
Maximum Voltage Drop Per Function
500.0 millivolts dc 1st radio interference
-
Source Impedance Rating Per Function
50.0 ohms 4th radio interference
-
Body Height
3.000 inches maximum
-
Load Impedance Per Function
50.0 ohms 2nd radio interference
-
Body Surface Treatment
tin
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
8.760 inches maximum
-
Operating Temp Range
+0.0/+60.0 deg celsius
-
Source Impedance Rating Per Function
50.0 ohms 2nd radio interference
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
3.500 inches maximum
-
Load Impedance Per Function
50.0 ohms 5th radio interference
-
Unthreaded Mounting Hole Diameter
0.218 inches nominal
-
Functional Terminal Type And Quantity
2 connector, receptacle output 2nd function
-
Load Impedance Per Function
50.0 ohms 1st radio interference
-
Source Impedance Rating Per Function
50.0 ohms 3rd radio interference