SM-A-726209-1
Circuit Breakers
CIRCUIT BREAKER
SM-A-726209-1
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Body Style
2a single pole type
-
Bushing Length
0.344 inches minimum and 0.406 inches maximum
-
Body Width
0.719 inches minimum and 0.781 inches maximum
-
Center To Center Distance Between Terminals Parallel To Length
1.529 inches minimum and 1.591 inches maximum
-
Fragility Factor
moderately rugged
-
Pole Quantity
1
-
Arc Quenching Method
magnetic blowout
-
Thread Quantity Per Inch
32
-
Maximum Continuous Load Current Rating Per Pole
25.0 amperes dc single location
-
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc single location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 dc single location
-
Circuit Protection Type
overcurrent single location
-
Trip Release Method
magnetic-hydraulic single location
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0
-
Reset Method
manual
-
Main Contact Tripping Mechanism Type
trip free
-
Manual Actuator Type And Quantity
1 toggle
-
Actuator Function
trip-reset
-
Body Length
1.969 inches minimum and 2.031 inches maximum
-
Case Material
plastic
-
Mounting Surface To Terminal End Distance
2.094 inches minimum and 2.156 inches maximum
-
Mounting Facility Type And Quantity
1 threaded bushing
-
Storage Type
general purpose warehouse
-
Trip Release Characteristic
time delay single location
-
Actuator Position Designation
at pole one
-
Internal Trip Release Configuration
series trip single location
-
Nominal Thread Size
0.375 inches
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.150 minimum at 200 pct and 15.000 maximum at 200 pct single location
-
Inclosure Protection Type For Which Designed
fungus resistant and moisture resistant
-
Unpackaged Unit Weight
2.200 ounces
-
Thread Series Designator
unef
-
Terminal Type And Quantity
2 tab w/screw