Technical Characteristics

  • Pole Quantity

    1 each section rear

  • Individual Section Quantity

    3

  • Contact Voltage Rating In Volts

    115.0 ac at sea level

  • Switch Contact Basic Design

    nonpile-up symmetrical

  • Thread Series Designator

    unef single mounting facility

  • Throw Quantity

    3 each section rear

  • Terminal Type

    printed circuit

  • Contact Voltage Rating In Volts

    28.0 dc at sea level

  • Switch Actuator Positioning Increment

    30.0 degrees single actuator

  • Nominal Thread Size

    0.250 inches single mounting facility

  • Shaft Diameter

    0.125 inches nominal single actuator

  • Switch Actuator Indexing Position Quantity

    3 single actuator

  • Switch Actuator Stop Device Type

    fixed stop single actuator

  • Flat Height

    0.094 inches nominal single actuator

  • Contact Switching Action

    breaks before makes each section rear

  • Nonturn Device Radius

    0.260 inches nominal at 3:00 o'clock

  • Err Default

    err default

  • Contact Load Current Rating

    250.0 milliamperes resistive load dc at sea level and 20.0 milliamperes inductive load dc at sea level

  • Overall Length

    2.183 inches nominal

  • Shaft Length

    0.375 inches nominal single actuator

  • First Flat Length

    0.250 inches nominal single actuator

  • Criticality Code Justification

    feat

  • Style Designator

    tap, circular, bushing mount

  • Special Features

    weapon system essential

  • Shaft Type

    round, flatted single actuator

  • End Item Identification

    lvirginia class cgn (41), tarawa class lha, yellowstone class ad-41, wasp class lhd, oliver perry class ffg, forrestal class cv, nimitz class cvn. nuclear power plants. cvn 68 class reactor fill auxiliary system.

  • Hazardous Locations/Environmental Protection

    explosion proof

  • Mounting Method

    threaded bushing single mounting facility

  • Contact Load Current Rating

    250.0 milliamperes resistive load ac at sea level and 50.0 milliamperes inductive load ac at sea level

  • Thread Class

    2a single mounting facility

  • Nonturn Device Type

    tab at 3:00 o'clock

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...