MIL-PRF-39019/2

Circuit Breakers

CIRCUIT BREAKER

MIL-PRF-39019/2

5925-01-037-6897

5925 - Circuit Breakers

Military Specifications

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • ~1

    data on certain environmental and performanc

  • Test Data Document

    81349-mil-c-39019 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • Fragility Factor

    moderately rugged

  • Trip Release Method

    magnetic single location

  • Specification/Standard Data

    81349-mil-c-39019/2 government specification

  • Internal Trip Release Configuration

    series trip single location

  • Manual Actuator Type And Quantity

    1 toggle

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes ac single location and 5.0 amperes dc single location

  • Case Material

    metal

  • Pole Quantity

    1

  • Switch Contact Arrangement

    single pole, double throw

  • Body Width

    0.594 inches minimum and 0.625 inches maximum

  • Circuit Protection Type

    overcurrent single location

  • Body Length

    1.531 inches minimum and 1.562 inches maximum

  • Thread Quantity Per Inch

    32

  • Nominal Thread Size

    0.375 inches

  • Inclosure Protection Type For Which Designed

    fungus resistant and hermetically sealed

  • Center To Center Distance Between Terminals Parallel To Length

    0.875 inches minimum and 0.906 inches maximum

  • Actuator Function

    trip-reset

  • Storage Type

    general purpose warehouse

  • Actuator Position Designation

    at pole one

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Reset Method

    manual

  • Bushing Length

    0.332 inches minimum and 0.380 inches maximum

  • Switch Terminal Type

    tab, solder lug

  • Terminal Type And Quantity

    2 wire hook

  • Trip Release Characteristic

    time delay single location

  • Switch Location And Position Designation

    internal at pole one

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac single location and 50.0 dc single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    300.0 ac single location and 500.0 dc single location

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Unpackaged Unit Weight

    50.0 grams

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.500 minimum at 200 pct single location and 9.000 maximum at 200 pct single location

  • Switch Voltage Rating And Type In Volts

    120.0 ac and 50.0 dc

  • Thread Series Designator

    unef

  • Mounting Surface To Terminal End Distance

    1.669 inches minimum and 1.700 inches maximum

  • Body Style

    single pole type

  • Frequency In Hertz

    400.0 single location

  • Switch Current Rating And Type In Amps

    0.5 ac and 0.5 dc

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...