MIL-C-39019/6

Circuit Breakers

CIRCUIT BREAKER

MIL-C-39019/6

5925-01-038-1332

5925 - Circuit Breakers

Military Specifications

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Maximum Continuous Load Current Rating Per Pole

    2.0 amperes ac all locations and 2.0 amperes dc all locations

  • Reset Method

    manual

  • Bushing Length

    0.375 inches nominal

  • Switch Current Rating And Type In Amps

    0.5 ac and 0.5 dc

  • Body Width

    1.872 inches nominal

  • Frequency In Hertz

    400.0 all locations

  • Thread Series Designator

    unef

  • Switch Voltage Rating And Type In Volts

    120.0 ac and 50.0 dc

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.500 minimum at 200 pct all locations and 9.000 maximum at 200 pct all locations

  • Specification/Standard Data

    81349-mil-c-39019/6 government specification

  • Terminal Type And Quantity

    6 wire hook

  • Test Data Document

    81349-mil-c-39019 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Switch Location And Position Designation

    internal at pole three

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Center To Center Distance Between Terminals Parallel To Width

    0.625 inches nominal

  • Actuator Function

    trip-reset

  • Mounting Surface To Terminal End Distance

    1.678 inches nominal

  • Internal Trip Release Configuration

    series trip all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    300.0 ac all locations and 500.0 dc all locations

  • Inclosure Protection Type For Which Designed

    fungus resistant and hermetically sealed

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations and 50.0 dc all locations

  • Nominal Thread Size

    0.375 inches

  • Thread Quantity Per Inch

    32

  • Trip Release Method

    magnetic all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Unpackaged Unit Weight

    150.0 grams

  • Actuator Position Designation

    at pole two

  • Body Length

    1.495 inches nominal

  • Switch Contact Arrangement

    single pole, double throw

  • Center To Center Distance Between Terminals Parallel To Length

    0.875 inches nominal

  • Body Style

    multipole-single actuator type

  • Case Material

    metal

  • Manual Actuator Type And Quantity

    1 toggle

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Fragility Factor

    moderately rugged

  • Switch Terminal Type

    tab, solder lug

  • Special Handling Feature

    magnetic

  • ~1

    data on certain environmental and performanc

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...