1150-612
Filters and Networks
FILTER,RADIO FREQUENCY INTERFERENCE
1150-612
FILTER,RADIO FREQUENCY INTERFERENCE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Load Impedance Per Function
50.0 ohms 2nd radio interference
-
Functional Terminal Type And Quantity
8 tab, solder lug input 1st function
-
Operating Current Rating Per Function In Amps
0.02 6th radio interference
-
Power Line Frequency Rating Per Function In Hertz
400.0 6th radio interference
-
Overall Length
5.310 inches nominal
-
Functional Terminal Type And Quantity
8 tab, solder lug output 2nd function
-
Special Features
8 functions
-
Operating Voltage Rating And Type Per Function
115.0 volts ac 1st radio interference 1st function
-
Source Impedance Rating Per Function
50.0 ohms 5th radio interference
-
Principal Circuitry Type Per Function
inductance-capacitance 2nd radio interference
-
Maximum Voltage Drop Per Function
1.15 volts ac 1st radio interference
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
4.562 inches nominal
-
Source Impedance Rating Per Function
50.0 ohms 3rd radio interference
-
Maximum Voltage Drop Per Function
1.15 volts ac 5th radio interference
-
Operating Current Rating Per Function In Amps
1.0 4th radio interference
-
Power Line Frequency Rating Per Function In Hertz
400.0 1st radio interference
-
Operating Temp Range
-55.0/+100.0 deg celsius
-
Load Impedance Per Function
50.0 ohms 3rd radio interference
-
Principal Circuitry Type Per Function
inductance-capacitance 1st radio interference
-
Operating Current Rating Per Function In Amps
1.0 1st radio interference
-
Style Designator
rectangular terminal/terminals on opposite surfaces
-
Vibration Resistance Range In Hertz
+10.0/+500.0
-
Source Impedance Rating Per Function
50.0 ohms 6th radio interference
-
Source Impedance Rating Per Function
50.0 ohms 1st radio interference
-
Body Length
3.000 inches nominal
-
Maximum Voltage Drop Per Function
1.15 volts ac 3rd radio interference
-
Maximum Temp Rise
25.0 deg celsius
-
Inclosure Type
encased
-
Maximum Voltage Drop Per Function
1.15 volts ac 2nd radio interference
-
Mounting Facility Type And Quantity
6 unthreaded hole
-
Power Line Frequency Rating Per Function In Hertz
400.0 2nd radio interference
-
Principal Circuitry Type Per Function
inductance-capacitance 6th radio interference
-
Power Line Frequency Rating Per Function In Hertz
400.0 3rd radio interference
-
Source Impedance Rating Per Function
50.0 ohms 4th radio interference
-
Power Line Frequency Rating Per Function In Hertz
400.0 4th radio interference
-
Operating Current Rating Per Function In Amps
0.02 5th radio interference
-
Power Line Frequency Rating Per Function In Hertz
400.0 5th radio interference
-
Operating Voltage Rating And Type Per Function
26.0 volts ac 6th radio interference 6th function
-
Operating Voltage Rating And Type Per Function
115.0 volts ac 2nd radio interference 2nd function
-
Unthreaded Mounting Hole Diameter
0.166 inches nominal
-
Load Impedance Per Function
50.0 ohms 4th radio interference
-
Principal Circuitry Type Per Function
inductance-capacitance 3rd radio interference
-
Functional Terminal Type And Quantity
2 turret ground 3rd function
-
Operating Current Rating Per Function In Amps
1.0 2nd radio interference
-
Body Width
4.940 inches nominal
-
Operating Voltage Rating And Type Per Function
115.0 volts ac 3rd radio interference 3rd function
-
Source Impedance Rating Per Function
50.0 ohms 2nd radio interference
-
Load Impedance Per Function
50.0 ohms 5th radio interference
-
Overall Height
1.250 inches nominal
-
Maximum Voltage Drop Per Function
260.0 millivolts ac 6th radio interference
-
Principal Circuitry Type Per Function
inductance-capacitance 4th radio interference
-
Operating Voltage Rating And Type Per Function
115.0 volts ac 5th radio interference 5th function
-
Maximum Voltage Drop Per Function
1.15 volts ac 4th radio interference
-
Operating Current Rating Per Function In Amps
1.0 3rd radio interference
-
Load Impedance Per Function
50.0 ohms 6th radio interference
-
Load Impedance Per Function
50.0 ohms 1st radio interference
-
Operating Voltage Rating And Type Per Function
115.0 volts ac 4th radio interference 4th function
-
Unpackaged Unit Weight
2.000 pounds
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
4.468 inches nominal
-
Principal Circuitry Type Per Function
inductance-capacitance 5th radio interference