CD-1-H3-U-100-125VDC-1

Circuit Breakers

CIRCUIT BREAKER

CD-1-H3-U-100-125VDC-1

5925-01-040-0438

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Mounting Slot Width

    0.178 inches nominal

  • Thread Quantity Per Inch

    32

  • Body Height

    1.026 inches nominal

  • Circuit Protection Type

    overcurrent single location

  • Maximum Continuous Load Current Rating Per Pole

    100.0 amperes dc single location

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Pole Quantity

    1

  • Manual Actuator Type And Quantity

    1 toggle

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.138 inches

  • Unthreaded Mounting Hole Diameter

    0.164 inches nominal

  • Trip Release Characteristic

    time delay single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    500.0 dc single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Body Length

    5.800 inches nominal

  • Body Style

    single pole type

  • Trip Release Method

    magnetic-hydraulic single location

  • Mounting Facility Type And Quantity

    2 threaded hole and 1 unthreaded hole and 1 slot

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.750 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    125.0 dc single location

  • Case Material

    plastic

  • Fragility Factor

    moderately rugged

  • Center To Center Distance Between Terminals Parallel To Length

    4.852 inches nominal

  • Body Width

    2.609 inches nominal

  • Thread Series Designator

    unc

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Terminal Type And Quantity

    2 screw

  • Trip Delay Time In Seconds Per Rated Continuous Current

    11.000 minimum at 200 pct single location and 100.000 maximum at 200 pct single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...