Technical Characteristics

  • Center To Center Distance Between Terminals Parallel To Length

    0.906 inches maximum

  • Switch Location And Position Designation

    internal at each pole

  • Frequency In Hertz

    400.0 all locations

  • Body Width

    1.938 inches maximum

  • Thread Series Designator

    unef

  • Unpackaged Unit Weight

    6.300 ounces

  • Terminal Type And Quantity

    6 wire hook

  • Switch Current Rating And Type In Amps

    1.0 ac and 0.5 dc

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    300.0 ac all locations

  • Fragility Factor

    moderately rugged

  • Switch Terminal Type

    tab, solder lug

  • Center To Center Distance Between Terminals Parallel To Width

    0.646 inches maximum

  • Body Length

    1.562 inches maximum

  • Arc Quenching Method

    magnetic blowout

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Case Material

    metal

  • Switch Voltage Rating And Type In Volts

    12.5 ac and 50.0 dc

  • Body Style

    multipole-single actuator type

  • Bushing Length

    0.375 inches maximum

  • Switch Contact Arrangement

    single pole, double throw

  • Maximum Continuous Load Current Rating Per Pole

    3.0 amperes ac all locations

  • Inclosure Protection Type For Which Designed

    hermetically sealed

  • Actuator Position Designation

    at pole two

  • Trip Release Method

    magnetic all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • Thread Quantity Per Inch

    32

  • Nominal Thread Size

    0.375 inches

  • Thread Pitch Diameters

    +0.3503/+0.3537 inches

  • Internal Trip Release Configuration

    series trip all locations

  • Auxiliary Switch Function And Quantity

    3 alarm

  • Test Data Document

    56232-338362 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)

  • Actuator Function

    trip-reset

  • Trip Release Characteristic

    time delay all locations

  • Storage Type

    general purpose warehouse

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.055 minimum at 200 pct all locations and 0.950 maximum at 200 pct all locations

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Reset Method

    manual

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    3

  • Mounting Surface To Terminal End Distance

    1.859 inches maximum

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...