Technical Characteristics

  • Winding Operating Voltage

    5.75 ac volts nominal single component 1st secondary

  • Frequency Rating

    26.0 kilohertz nominal single component

  • Winding Function And Quantity

    2 primary single component and 4 secondary single component

  • Winding Operating Current

    50.0 milliamperes ac maximum single component 4th secondary

  • Body Length

    0.775 inches nominal

  • Maximum Transformer Power Rating

    7.12 volt-ampere single component

  • Winding Power Rating

    1.44 volts-amperes single component 2nd secondary

  • Winding Operating Current

    500.0 milliamperes ac maximum single component 1st secondary

  • Mounting Hole Diameter

    0.169 inches nominal single group

  • Maximum Operating Temp

    155.0 deg celsius

  • Winding Power Rating

    1.44 volts-amperes single component 3rd secondary

  • Inclosure Type

    fully inclosed

  • Winding Operating Voltage

    2.88 ac volts nominal single component 2nd secondary

  • Winding Operating Voltage

    2.88 ac volts nominal single component 3rd secondary

  • Mounting Method

    unthreaded hole single group

  • Winding Operating Current

    500.0 milliamperes ac maximum single component 2nd secondary

  • Winding Power Rating

    1.34 volts-amperes single component 4th secondary

  • Reliability Indicator

    not established

  • Winding Operating Current

    500.0 milliamperes ac maximum single component 3rd secondary

  • Input-Output Phase Relationship

    single phase to single phase single component

  • Terminal Type And Quantity

    11 pin and 7 turret

  • Mounting Facility Quantity

    1 single group

  • Winding Operating Voltage

    26.87 ac volts nominal single component all primary

  • Body Outside Diameter

    1.000 inches maximum

  • Winding Power Rating

    2.9 volts-amperes single component 1st secondary

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...