FA-36025

Circuit Breakers

CIRCUIT BREAKER

FA-36025

5925-01-042-5073

5925 - Circuit Breakers

Square D Co

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Operating Voltage Type And Rating Per Pole In Volts

    600.0 ac all locations and 250.0 dc all locations

  • Center To Center Distance Between Terminals Parallel To Length

    4.704 inches nominal

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Trip Release Method

    thermal-magnetic all locations

  • Body Height

    3.000 inches nominal

  • Actuator Position Designation

    at pole two

  • Body Style

    multipole-single actuator type

  • Manual Actuator Type And Quantity

    1 toggle

  • Frequency In Hertz

    60.0 all locations

  • Terminal Type And Quantity

    6 compression

  • Main Contact Tripping Mechanism Type

    trip free

  • Boss Height

    0.125 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    4.704 inches nominal

  • Body Length

    6.000 inches nominal

  • Trip Delay Time In Seconds Per Rated Continuous Current

    120.000 maximum at 200 pct all locations

  • Unthreaded Mounting Hole Diameter

    0.172 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    25.0 amperes ac all locations and 25.0 amperes dc all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.500 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    7500.0 ac all locations and 5000.0 dc all locations

  • Case Material

    plastic

  • Mounting Facility Type And Quantity

    6 unthreaded hole

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Inclosure Protection Type For Which Designed

    dustproof

  • Reset Method

    manual

  • Center To Center Distance Between Terminals Parallel To Width

    1.500 inches nominal

  • Trip Release Ambient Temp Rating

    40.0 deg celsius nominal all locations

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Body Width

    4.469 inches nominal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...