TSA-228-25-5XX1

Filters and Networks

FILTER,BAND PASS

TSA-228-25-5XX1

5915-01-043-1965

5915 - Filters and Networks

Telonic Berkeley Inc.

FILTER,BAND PASS

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Inclosure Type

    encased

  • Specified Frequencies Of Discrimination Per Function

    190.00 megahertz blank and 240.50 megahertz blank and 215.50 megahertz blank and 276.00 megahertz blank

  • Body Length

    2.250 inches nominal

  • Insertion Loss At Reference Frequency Per Function In Decibels

    2.2 blank

  • Functional Terminal Type And Quantity

    1 wire lead output 2nd function

  • Vibration Resistance Range In Hertz

    +10.0/+2000.0

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Body Material

    metal

  • Style Designator

    rectangular terminal/terminals on one surface

  • Operating Temp Range

    -55.0/+65.0 deg celsius

  • Functional Terminal Type And Quantity

    2 wire lead ground 3rd function

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.564 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.126 inches nominal

  • Average Life Rating In Hours

    10000.0

  • Source Impedance Rating Per Function

    50.0 ohms blank

  • Frequency Band Width Per Function

    215.50 megahertz blank and 240.50 megahertz blank

  • Load Impedance Per Function

    50.0 ohms blank

  • Body Height

    0.380 inches nominal

  • Voltage Standing Wave Ratio Per Function

    1.5 blank

  • Nominal Thread Size

    0.086 inches

  • Unpackaged Unit Weight

    3.000 ounces

  • Discrimination At Specified Frequencies Per Function In Decibels

    50.0 minimum blank and 3.0 maximum blank and 3.0 maximum blank and 50.0 minimum blank

  • Average Power Rating Per Function

    3.0 watts blank

  • Overall Height

    0.540 inches minimum

  • Mounting Facility Screw Thread Series Designator

    unc

  • Functional Terminal Type And Quantity

    1 wire lead input 1st function

  • Voltage Standing Wave Ratio Frequency Limits Per Function

    218.0 megahertz blank and 238.0 megahertz blank

  • Body Width

    0.690 inches nominal

  • Reference Frequency Per Function

    228.0 megahertz blank

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...