9176315-10

Circuit Breakers

CIRCUIT BREAKER

9176315-10

5925-01-043-3152

5925 - Circuit Breakers

U S Army Aviation And Missile

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Circuit Protection Type

    overcurrent all locations

  • Thread Series Designator

    unc

  • Operating Voltage Type And Rating Per Pole In Volts

    416.0 ac all locations

  • Body Width

    3.063 inches nominal

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Switch Location And Position Designation

    internal at pole three

  • Body Length

    3.719 inches nominal

  • Precious Material

    silver

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Center To Center Distance Between Terminals Parallel To Width

    1.030 inches nominal

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Internal Trip Release Configuration

    series trip all locations

  • Switch Current Rating And Type In Amps

    5.0 ac and 5.0 dc

  • Center To Center Distance Between Terminals Parallel To Length

    3.060 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    6.0 amperes ac all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.400 minimum at 200 pct all locations and 1.000 maximum at 200 pct all locations

  • Inclosure Protection Type For Which Designed

    fungus resistant and humidity resistant and vibration resistant and salt spray proof

  • Thread Quantity Per Inch

    32

  • Trip Release Method

    magnetic all locations

  • Body Style

    multipole-multiple actuator type

  • Switch Voltage Rating And Type In Volts

    115.0 ac and 28.0 dc

  • Switch Contact Arrangement

    single pole, double throw

  • Precious Material And Location

    terminal and terminal hardware surfaces silver

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 all locations

  • Nominal Thread Size

    0.138 inches

  • Boss Height

    0.156 inches nominal

  • Mounting Surface To Terminal End Distance

    3.120 inches minimum and 3.240 inches maximum

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1500.0 ac all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.030 inches nominal

  • Frequency In Hertz

    400.0 all locations

  • Switch Terminal Type

    pin

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.750 inches nominal

  • Manual Actuator Type And Quantity

    3 toggle

  • Unpackaged Unit Weight

    2.000 pounds

  • Case Material

    plastic

  • Terminal Type And Quantity

    6 threaded stud

  • Fragility Factor

    moderately rugged

  • Special Handling Feature

    magnetic

  • Pole Quantity

    3

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...